Titanium and its alloys are widely employed in commercial dental devices. Because the surface morphology and chemical composition of Ti-based dental implants play a relevant role in osseointegration, three different commercial threaded implants have been investigated by scanning electron microscopy and X-ray photoelectron spectroscopy (XPS). The Implants A and C were made of pure Ti whereas the Implant B was made of Ti6Al4V alloy. Obtained results evidenced the common features and differences due to specific process parameters used in the treatments of mordanting and sandblasting for surface roughening. Implant A exhibits a uniform surface covered by very small dimples of about 1–2 μm. The surface of Implant B is not homogeneous: The thread tops present an irregular morphology (dimples size >10 μm) while finer dimples (about 1 μm) are observed along the thread flanks and valleys. Implant C shows an irregular morphology with dimples of different sizes and shapes distributed on thread tops, flanks, and valleys. XPS analyses revealed the presence of metal oxides: TiO2 in all the implants; Al2O3 and V2O5 only in the implant B. Moreover, these results demonstrated that Mg2SiO4 is present on the surface of Implant A, probably due to a specific preparation process. Obtained results have been discussed on the basis of the factors promoting the osseointegration.

Morphology and microchemistry study of three commercial dental implants / Ausiello, P.; Bolli, E.; Kaciulis, S.; Gloria, A.; Lanzotti, A.; Martorelli, M.; Mezzi, A.; Montanari, R.; Richetta, M.; Varone, A.. - In: SURFACE AND INTERFACE ANALYSIS. - ISSN 0142-2421. - (2022). [10.1002/sia.7166]

Morphology and microchemistry study of three commercial dental implants

Ausiello P.;Gloria A.;Lanzotti A.;Martorelli M.;
2022

Abstract

Titanium and its alloys are widely employed in commercial dental devices. Because the surface morphology and chemical composition of Ti-based dental implants play a relevant role in osseointegration, three different commercial threaded implants have been investigated by scanning electron microscopy and X-ray photoelectron spectroscopy (XPS). The Implants A and C were made of pure Ti whereas the Implant B was made of Ti6Al4V alloy. Obtained results evidenced the common features and differences due to specific process parameters used in the treatments of mordanting and sandblasting for surface roughening. Implant A exhibits a uniform surface covered by very small dimples of about 1–2 μm. The surface of Implant B is not homogeneous: The thread tops present an irregular morphology (dimples size >10 μm) while finer dimples (about 1 μm) are observed along the thread flanks and valleys. Implant C shows an irregular morphology with dimples of different sizes and shapes distributed on thread tops, flanks, and valleys. XPS analyses revealed the presence of metal oxides: TiO2 in all the implants; Al2O3 and V2O5 only in the implant B. Moreover, these results demonstrated that Mg2SiO4 is present on the surface of Implant A, probably due to a specific preparation process. Obtained results have been discussed on the basis of the factors promoting the osseointegration.
2022
Morphology and microchemistry study of three commercial dental implants / Ausiello, P.; Bolli, E.; Kaciulis, S.; Gloria, A.; Lanzotti, A.; Martorelli, M.; Mezzi, A.; Montanari, R.; Richetta, M.; Varone, A.. - In: SURFACE AND INTERFACE ANALYSIS. - ISSN 0142-2421. - (2022). [10.1002/sia.7166]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/921209
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact