The green fluorescent protein YFP-H148Q is sensitive to halides by a mechanism involving halide binding and a shift in pK(a). However, a limitation of YFP-H148Q is its low halide sensitivity, with K(d)>100 mM for Cl(-). Indicators with improved sensitivities are needed for cell transport studies, particularly in drug discovery by high-throughput screening, and for measurement of Cl(-) concentration in subcellular organelles. YFP-H148Q libraries were generated in which pairs of residues in the vicinity of the halide binding site were randomly mutated. An automated procedure was developed to screen bacterial colonies for improved halide sensitivity. Analysis of 1536 clones revealed improved anion sensitivities with K(d) down to 2 mM for I(-) (I152L), 40 mM for Cl(-) (V163S), and 10 mM for NO(3)(-) (I152L). The anion-sensitive mechanism of these indicators was established and their utility in cells was demonstrated using transfected cells expressing the cystic fibrosis transmembrane conductance regulator chloride channel.

Green fluorescent protein-based halide indicators with improved chloride and iodide affinities / Galietta, L J; Haggie, P M; Verkman, A S. - In: FEBS LETTERS. - ISSN 0014-5793. - 499:3(2001), p. 220-4.

Green fluorescent protein-based halide indicators with improved chloride and iodide affinities

Galietta, L J;
2001

Abstract

The green fluorescent protein YFP-H148Q is sensitive to halides by a mechanism involving halide binding and a shift in pK(a). However, a limitation of YFP-H148Q is its low halide sensitivity, with K(d)>100 mM for Cl(-). Indicators with improved sensitivities are needed for cell transport studies, particularly in drug discovery by high-throughput screening, and for measurement of Cl(-) concentration in subcellular organelles. YFP-H148Q libraries were generated in which pairs of residues in the vicinity of the halide binding site were randomly mutated. An automated procedure was developed to screen bacterial colonies for improved halide sensitivity. Analysis of 1536 clones revealed improved anion sensitivities with K(d) down to 2 mM for I(-) (I152L), 40 mM for Cl(-) (V163S), and 10 mM for NO(3)(-) (I152L). The anion-sensitive mechanism of these indicators was established and their utility in cells was demonstrated using transfected cells expressing the cystic fibrosis transmembrane conductance regulator chloride channel.
2001
Green fluorescent protein-based halide indicators with improved chloride and iodide affinities / Galietta, L J; Haggie, P M; Verkman, A S. - In: FEBS LETTERS. - ISSN 0014-5793. - 499:3(2001), p. 220-4.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/739455
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 293
social impact