We report, herein, novel processes of nanofabrication techniques for few molecules detection by generating surface plasmons, thus giving a giant electric field in a controllable and reproducible manner. Surface enhanced Raman scattering (SERS) measurements are performed for different proteins, namely, lysozyme, ribonuclease-B, bovin serum albumin, ferritin, and myoglobin in the temperature range between –65°C and 90°C, using “Device1”, which is fabricated by means of e-beam and electro-plating technique. The calculation shows the possible detection of myoglobin concentration down to attomole. The in-depth analysis even for small conformational changes is performed using 2D Raman correlation analysis and difference Raman analysis in order to gain straightforward understanding of proteins undergoing thermodynamical perturbation. “Device2” is fabricated by e-beam and metal electroless techniques to investigate the Rhodamine 6G (R6G) of different concentrations. Modifying this device by using bimetal (Ag and Au) electroless deposition permits us the further enhancement in Raman signal and better durability.

Low Concentration Protein Detection Using Novel SERS Devices / Das, Gobind; Gentile, Francesco; Coluccio, Maria Laura; Cojoc, G.; Mecarini, Federico; De Angelis, Francesco; Candeloro, Patrizio; Liberale, Carlo; Di Fabrizio, Enzo. - (2011), pp. 191-210. [10.1007/978-3-642-15175-0_12]

Low Concentration Protein Detection Using Novel SERS Devices

GENTILE, Francesco;
2011

Abstract

We report, herein, novel processes of nanofabrication techniques for few molecules detection by generating surface plasmons, thus giving a giant electric field in a controllable and reproducible manner. Surface enhanced Raman scattering (SERS) measurements are performed for different proteins, namely, lysozyme, ribonuclease-B, bovin serum albumin, ferritin, and myoglobin in the temperature range between –65°C and 90°C, using “Device1”, which is fabricated by means of e-beam and electro-plating technique. The calculation shows the possible detection of myoglobin concentration down to attomole. The in-depth analysis even for small conformational changes is performed using 2D Raman correlation analysis and difference Raman analysis in order to gain straightforward understanding of proteins undergoing thermodynamical perturbation. “Device2” is fabricated by e-beam and metal electroless techniques to investigate the Rhodamine 6G (R6G) of different concentrations. Modifying this device by using bimetal (Ag and Au) electroless deposition permits us the further enhancement in Raman signal and better durability.
2011
Low Concentration Protein Detection Using Novel SERS Devices / Das, Gobind; Gentile, Francesco; Coluccio, Maria Laura; Cojoc, G.; Mecarini, Federico; De Angelis, Francesco; Candeloro, Patrizio; Liberale, Carlo; Di Fabrizio, Enzo. - (2011), pp. 191-210. [10.1007/978-3-642-15175-0_12]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/678327
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact