A sensitive, specific and fast method to quantify 3α-hydroxytibolone in human plasma using deuterated 3α-hydroxytibolone (d5) as internal standard is described. The analyte and the internal standard were extracted from plasma (900 μL) by liquid-liquid extraction using ethyl ether/hexane (50/50, v/v) and ammonium hydroxide (50%). The extracts were analyzed by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry without derivatization. Chromatography was performed isocratically on a Gemini-NX™ C18 5 μm (150 × 4.6 mm i. d.) column. The method had a chromatographic run time of 3.75 min and a linear calibration curve over the range 1–100 ng/mL. The limit of quantification validated was 1 ng/mL. This method was used to assess the bioequivalence between two different tibolone oral formulations: Livolon (1.25 mg tablet) provided by Biolab Sanus Farmacêutica (Brazil), as the test formulation, and Libiam™ (1.25 mg tablet) produced by Libbs Farmacêutica (Brazil), as the reference formulation. A single 3.75 mg dose of each formulation was administered to 46 postmenopausal female healthy volunteers. The study was conducted in an open, randomized, two-period crossover balanced design with a 2 week washout interval between the doses. The 90% confidence interval for Cmax, AUC(0-last) and AUC(0-inf) individual test/reference ratios were 97.48–111.51, 95.35–103.20 and 96.42–103.86, respectively. It is concluded that Livolon (1.25 mg tablet) is bioequivalent to Libiam™ (1.25 mg tablet), with regards to both rate and extent of absorption.

Quantification of 3α-hydroxytibolone in human plasma by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS): Application in a bioequivalence study in healthy postmenopausal volunteers / Portela, Lucas Azevedo; Laurito, Tiago Luders; Severino, Beatrice; Perissutti, Elisa; Mendes, Gustavo D.; Moreno, Ronilson Agnaldo; De Nucci, Gilberto. - In: ANALYTICAL CHEMISTRY RESEARCH. - ISSN 2214-1812. - 8:(2016), pp. 16-25. [10.1016/j.ancr.2016.04.002]

Quantification of 3α-hydroxytibolone in human plasma by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS): Application in a bioequivalence study in healthy postmenopausal volunteers

SEVERINO, BEATRICE;PERISSUTTI, ELISA;
2016

Abstract

A sensitive, specific and fast method to quantify 3α-hydroxytibolone in human plasma using deuterated 3α-hydroxytibolone (d5) as internal standard is described. The analyte and the internal standard were extracted from plasma (900 μL) by liquid-liquid extraction using ethyl ether/hexane (50/50, v/v) and ammonium hydroxide (50%). The extracts were analyzed by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry without derivatization. Chromatography was performed isocratically on a Gemini-NX™ C18 5 μm (150 × 4.6 mm i. d.) column. The method had a chromatographic run time of 3.75 min and a linear calibration curve over the range 1–100 ng/mL. The limit of quantification validated was 1 ng/mL. This method was used to assess the bioequivalence between two different tibolone oral formulations: Livolon (1.25 mg tablet) provided by Biolab Sanus Farmacêutica (Brazil), as the test formulation, and Libiam™ (1.25 mg tablet) produced by Libbs Farmacêutica (Brazil), as the reference formulation. A single 3.75 mg dose of each formulation was administered to 46 postmenopausal female healthy volunteers. The study was conducted in an open, randomized, two-period crossover balanced design with a 2 week washout interval between the doses. The 90% confidence interval for Cmax, AUC(0-last) and AUC(0-inf) individual test/reference ratios were 97.48–111.51, 95.35–103.20 and 96.42–103.86, respectively. It is concluded that Livolon (1.25 mg tablet) is bioequivalent to Libiam™ (1.25 mg tablet), with regards to both rate and extent of absorption.
2016
Quantification of 3α-hydroxytibolone in human plasma by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS): Application in a bioequivalence study in healthy postmenopausal volunteers / Portela, Lucas Azevedo; Laurito, Tiago Luders; Severino, Beatrice; Perissutti, Elisa; Mendes, Gustavo D.; Moreno, Ronilson Agnaldo; De Nucci, Gilberto. - In: ANALYTICAL CHEMISTRY RESEARCH. - ISSN 2214-1812. - 8:(2016), pp. 16-25. [10.1016/j.ancr.2016.04.002]
File in questo prodotto:
File Dimensione Formato  
Analytical Chemistry Research, 8, 2016, 16-25.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Dominio pubblico
Dimensione 1.3 MB
Formato Adobe PDF
1.3 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/634819
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact