The current approach for catheter ablation (CA) of accessory pathways (AP) includes the use of standard catheters under fluoroscopic visualization. We hypothesize that use of contact force (CF) irrigated tip catheters might increase procedural safety in pediatric patients compared to standard irrigated tip catheters, by decreasing the number of radiofrequency (RF) pulses required to obtain AP elimination. Seventy-one pediatric patients (13.7 ± 2.5 years, 45 male) with ventricular pre-excitation were enrolled in the study. CA was performed with a standard irrigated tip catheter up to June 2013 in 41 patients (Group S) and with a CF sensing irrigated tip catheter later on in 30 patients (Group CF). In the Group CF, RF was applied with a minimal CF of 5 g; CF > 35 g was avoided. Group CF procedures required less fluoroscopy (6.8 ± 4.8 min), compared to Group S (12.2 ± 10.8 min, p = 0.007). The number of RF pulses was smaller in Group CF compared to Group S (2.5 ± 2.0 vs 5.5 ± 1.9, p < 0.01). The mean CF during the effective RF pulse was 18 ± 7.7 g, force–time integral was 1040.7 ± 955.9 gs, Ablation Index was 513.0 ± 214.2. The procedure was acutely successful in 70 patients; at 12 months follow-up 2 patients had AP recurrence, one for each group. No major complications were reported. The use of CF irrigated tip catheters was associated with a smaller number of RF pulses and less fluoroscopy, as compared to mapping and ablation with standard irrigated tip catheters. © 2019, Springer Science+Business Media, LLC, part of Springer Nature.

Usefulness of Electroanatomical Mapping with Contact Force Monitoring for Accessory Pathways Ablation in Pediatric Population / Gulletta, S; Vergara, P; Gigli, L; D’Angelo, G; Radinovic, A; Melania Barbaro, C; Trevisi, N; Della Bella, P.. - In: PEDIATRIC CARDIOLOGY. - ISSN 0172-0643. - 40:4(2019), pp. 713-718. [10.1007/s00246-019-02051-0]

Usefulness of Electroanatomical Mapping with Contact Force Monitoring for Accessory Pathways Ablation in Pediatric Population

VERGARA P;
2019

Abstract

The current approach for catheter ablation (CA) of accessory pathways (AP) includes the use of standard catheters under fluoroscopic visualization. We hypothesize that use of contact force (CF) irrigated tip catheters might increase procedural safety in pediatric patients compared to standard irrigated tip catheters, by decreasing the number of radiofrequency (RF) pulses required to obtain AP elimination. Seventy-one pediatric patients (13.7 ± 2.5 years, 45 male) with ventricular pre-excitation were enrolled in the study. CA was performed with a standard irrigated tip catheter up to June 2013 in 41 patients (Group S) and with a CF sensing irrigated tip catheter later on in 30 patients (Group CF). In the Group CF, RF was applied with a minimal CF of 5 g; CF > 35 g was avoided. Group CF procedures required less fluoroscopy (6.8 ± 4.8 min), compared to Group S (12.2 ± 10.8 min, p = 0.007). The number of RF pulses was smaller in Group CF compared to Group S (2.5 ± 2.0 vs 5.5 ± 1.9, p < 0.01). The mean CF during the effective RF pulse was 18 ± 7.7 g, force–time integral was 1040.7 ± 955.9 gs, Ablation Index was 513.0 ± 214.2. The procedure was acutely successful in 70 patients; at 12 months follow-up 2 patients had AP recurrence, one for each group. No major complications were reported. The use of CF irrigated tip catheters was associated with a smaller number of RF pulses and less fluoroscopy, as compared to mapping and ablation with standard irrigated tip catheters. © 2019, Springer Science+Business Media, LLC, part of Springer Nature.
2019
Usefulness of Electroanatomical Mapping with Contact Force Monitoring for Accessory Pathways Ablation in Pediatric Population / Gulletta, S; Vergara, P; Gigli, L; D’Angelo, G; Radinovic, A; Melania Barbaro, C; Trevisi, N; Della Bella, P.. - In: PEDIATRIC CARDIOLOGY. - ISSN 0172-0643. - 40:4(2019), pp. 713-718. [10.1007/s00246-019-02051-0]
File in questo prodotto:
File Dimensione Formato  
47 Gulletta WPW 2019.pdf

non disponibili

Licenza: Non specificato
Dimensione 657.42 kB
Formato Adobe PDF
657.42 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/997992
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact