BACKGROUND: Biventricular endocardial pacing (BiV ENDO) is a therapy for heart failure patients who cannot receive transvenous epicardial cardiac resynchronization therapy (CRT) or have not responded adequately to CRT. BiV ENDO CRT can be delivered by a new wireless LV ENDO pacing system (WiSE-CRT system; EBR Systems, Sunnyvale, CA), without the requirement for lifelong anticoagulation. OBJECTIVE: The purpose of this study was to assess the safety and efficacy of the WiSE-CRT system during real-world clinical use in an international registry. METHODS: Data were prospectively collected from 14 centers implanting the WiSE-CRT system as part of the WiCS-LV Post Market Surveillance Registry. (ClinicalTrials.gov Identifier: NCT02610673). RESULTS: Ninety patients from 14 European centers underwent implantation with the WiSE-CRT system. Patients were predominantly male, age 68.2 +/- 10.5 years, left ventricular ejection fraction 30.6% +/- 8.9%, mean QRS duration 180.7 +/- 27.0 ms, and 40% with ischemic etiology. Successful implantation and delivery of BiV ENDO pacing was achieved in 94.4% of patients. Acute (<24 hours), 1- to 30-day, and 1- to 6-month complications rates were 4.4%, 18.8%, and 6.7%, respectively. Five deaths (5.6%) occurred within 6 months (3 procedure related). Seventy percent of patients had improvement in heart failure symptoms. CONCLUSION: BiV ENDO pacing with the WiSE-CRT system seems to be technically feasible, with a high success rate. Three procedural deaths occurred during the study. Procedural complications mandate adequate operator training and implantation at centers with immediately available cardiothoracic and vascular surgical support.
Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: A multicenter international registry of the WiSE-CRT pacing system / Sieniewicz, B. J.; Betts, T. R.; James, S.; Turley, A.; Butter, C.; Seifert, M.; Boersma, L. V. A.; Riahi, S.; Neuzil, P.; Biffi, M.; Diemberger, I.; Vergara, P; Arnold, M.; Keane, D. T.; Defaye, P.; Deharo, J. C.; Chow, A.; Schilling, R.; Behar, J.; Rinaldi, C. A.. - In: HEART RHYTHM. - ISSN 1547-5271. - 17:(2020), pp. 1291-1297. [10.1016/j.hrthm.2020.03.002]
Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: A multicenter international registry of the WiSE-CRT pacing system
VERGARA P;
2020
Abstract
BACKGROUND: Biventricular endocardial pacing (BiV ENDO) is a therapy for heart failure patients who cannot receive transvenous epicardial cardiac resynchronization therapy (CRT) or have not responded adequately to CRT. BiV ENDO CRT can be delivered by a new wireless LV ENDO pacing system (WiSE-CRT system; EBR Systems, Sunnyvale, CA), without the requirement for lifelong anticoagulation. OBJECTIVE: The purpose of this study was to assess the safety and efficacy of the WiSE-CRT system during real-world clinical use in an international registry. METHODS: Data were prospectively collected from 14 centers implanting the WiSE-CRT system as part of the WiCS-LV Post Market Surveillance Registry. (ClinicalTrials.gov Identifier: NCT02610673). RESULTS: Ninety patients from 14 European centers underwent implantation with the WiSE-CRT system. Patients were predominantly male, age 68.2 +/- 10.5 years, left ventricular ejection fraction 30.6% +/- 8.9%, mean QRS duration 180.7 +/- 27.0 ms, and 40% with ischemic etiology. Successful implantation and delivery of BiV ENDO pacing was achieved in 94.4% of patients. Acute (<24 hours), 1- to 30-day, and 1- to 6-month complications rates were 4.4%, 18.8%, and 6.7%, respectively. Five deaths (5.6%) occurred within 6 months (3 procedure related). Seventy percent of patients had improvement in heart failure symptoms. CONCLUSION: BiV ENDO pacing with the WiSE-CRT system seems to be technically feasible, with a high success rate. Three procedural deaths occurred during the study. Procedural complications mandate adequate operator training and implantation at centers with immediately available cardiothoracic and vascular surgical support.| File | Dimensione | Formato | |
|---|---|---|---|
|
53 Sieniewicz WiSE HR 2020.pdf
non disponibili
Licenza:
Non specificato
Dimensione
844.67 kB
Formato
Adobe PDF
|
844.67 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


