Background: Severe tricuspid regurgitation (TR) often causes substantial impairment in patient-reported health status (ie, symptoms, physical and social function, and quality of life), which may improve with transcatheter tricuspid valve replacement (TTVR). Objectives: We performed an in-depth analysis of health status of patients enrolled in the TRISCEND (Edwards EVOQUE Transcatheter Tricuspid Valve Replacement: Pivotal Clinical Investigation of Safety and Clinical Efficacy using a Novel Device) II pivotal trial to help quantify the benefit of intervention to patients. Methods: The TRISCEND II pivotal trial randomized 400 patients with symptomatic and severe or greater TR 2:1 to TTVR with the EVOQUE tricuspid valve replacement system plus optimal medical therapy (OMT) or OMT alone. Health status was assessed with the Kansas City Cardiomyopathy Questionnaire and the 36-Item Short Form Health Survey. Changes in health status over 1 year were compared between treatment groups using mixed-effects repeated-measures models. Results: The analysis cohort included 392 patients, of whom 259 underwent attempted TTVR and 133 received OMT alone (mean age 79.2 ± 7.6 years, 75.5% women, 56.1% with massive or torrential TR). Patients had substantially impaired health status at baseline (mean Kansas City Cardiomyopathy Questionnaire Overall Summary Score [KCCQ-OS] 52.1 ± 22.8; mean 36-Item Short Form Health Survey physical component summary score 35.2 ± 8.4). TTVR+OMT patients reported significantly greater improvement in both disease-specific and generic health status at each follow-up time point. Mean between-group differences in the KCCQ-OS favored TTVR+OMT at each time point: 11.8 points (95% CI: 7.4-16.3 points) at 30 days, 20.8 points (95% CI: 16.1-25.5 points) at 6 months, and 17.8 points (95% CI: 13.0-22.5 points) at 1 year. In subgroup analyses, TTVR+OMT improved health status to a greater extent among patients with torrential or massive TR vs severe TR (treatment effect 23.3 vs 22.6 vs 11.3; interaction P = 0.049). At 1 year, 64.6% of TTVR+OMT patients were alive and well (KCCQ-OS ≥60 points and no decline of ≥10 points from baseline) compared with 31.0% with OMT alone. Conclusions: Compared with OMT alone, treatment of patients with symptomatic and severe or greater TR with TTVR+OMT resulted in substantial improvement in patients’ symptoms, function, and quality of life. These benefits were evident 30 days after TTVR, continued to increase through 6 months, and remained durable through 1 year. (TRISCEND II Pivotal Trial [Edwards EVOQUE Transcatheter Tricuspid Valve Replacement: Pivotal Clinical Investigation of Safety and Clinical Efficacy using a Novel Device]; NCT04482062)
Quality of Life After Transcatheter Tricuspid Valve Replacement: 1-Year Results From TRISCEND II Pivotal Trial / Arnold, S. V.; Hahn, R. T.; Thourani, V. H.; Makkar, R.; Makar, M.; Sharma, R. P.; Haeffele, C.; Davidson, C. J.; Narang, A.; O'Neill, B.; Lee, J.; Yadav, P.; Zahr, F.; Chadderdon, S.; Eleid, M.; Pislaru, S.; Smith, R.; Szerlip, M.; Whisenant, B.; Sekaran, N.; Garcia, S.; Stewart-Dehner, T.; Grayburn, P. A.; Sannino, A.; Snyder, C.; Zhang, Y.; Mack, M. J.; Leon, M. B.; Lurz, P.; Kodali, S.; Cohen, D. J.. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - (2024). [10.1016/j.jacc.2024.10.067]
Quality of Life After Transcatheter Tricuspid Valve Replacement: 1-Year Results From TRISCEND II Pivotal Trial
Sannino A.;
2024
Abstract
Background: Severe tricuspid regurgitation (TR) often causes substantial impairment in patient-reported health status (ie, symptoms, physical and social function, and quality of life), which may improve with transcatheter tricuspid valve replacement (TTVR). Objectives: We performed an in-depth analysis of health status of patients enrolled in the TRISCEND (Edwards EVOQUE Transcatheter Tricuspid Valve Replacement: Pivotal Clinical Investigation of Safety and Clinical Efficacy using a Novel Device) II pivotal trial to help quantify the benefit of intervention to patients. Methods: The TRISCEND II pivotal trial randomized 400 patients with symptomatic and severe or greater TR 2:1 to TTVR with the EVOQUE tricuspid valve replacement system plus optimal medical therapy (OMT) or OMT alone. Health status was assessed with the Kansas City Cardiomyopathy Questionnaire and the 36-Item Short Form Health Survey. Changes in health status over 1 year were compared between treatment groups using mixed-effects repeated-measures models. Results: The analysis cohort included 392 patients, of whom 259 underwent attempted TTVR and 133 received OMT alone (mean age 79.2 ± 7.6 years, 75.5% women, 56.1% with massive or torrential TR). Patients had substantially impaired health status at baseline (mean Kansas City Cardiomyopathy Questionnaire Overall Summary Score [KCCQ-OS] 52.1 ± 22.8; mean 36-Item Short Form Health Survey physical component summary score 35.2 ± 8.4). TTVR+OMT patients reported significantly greater improvement in both disease-specific and generic health status at each follow-up time point. Mean between-group differences in the KCCQ-OS favored TTVR+OMT at each time point: 11.8 points (95% CI: 7.4-16.3 points) at 30 days, 20.8 points (95% CI: 16.1-25.5 points) at 6 months, and 17.8 points (95% CI: 13.0-22.5 points) at 1 year. In subgroup analyses, TTVR+OMT improved health status to a greater extent among patients with torrential or massive TR vs severe TR (treatment effect 23.3 vs 22.6 vs 11.3; interaction P = 0.049). At 1 year, 64.6% of TTVR+OMT patients were alive and well (KCCQ-OS ≥60 points and no decline of ≥10 points from baseline) compared with 31.0% with OMT alone. Conclusions: Compared with OMT alone, treatment of patients with symptomatic and severe or greater TR with TTVR+OMT resulted in substantial improvement in patients’ symptoms, function, and quality of life. These benefits were evident 30 days after TTVR, continued to increase through 6 months, and remained durable through 1 year. (TRISCEND II Pivotal Trial [Edwards EVOQUE Transcatheter Tricuspid Valve Replacement: Pivotal Clinical Investigation of Safety and Clinical Efficacy using a Novel Device]; NCT04482062)| File | Dimensione | Formato | |
|---|---|---|---|
|
TriscendII_QualityLife_JACC.pdf
non disponibili
Tipologia:
Versione Editoriale (PDF)
Licenza:
Non specificato
Dimensione
770.24 kB
Formato
Adobe PDF
|
770.24 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


