Featured Application: The use of a new and valid reference system for analysis of facial scans might improve the quality of the assessment of orthodontics and orthognathic outcomes. Background: The aim of this study was to evaluate the accuracy and the repeatability of two reference systems for three-dimensional facial scans (FSs) compared with a reference system based on cone-beam computed tomography (CBCT). Subjects and methods: A total of sixty subjects, thirty growing participants (8–17 years old) and thirty non-growing participants (older than 21 years old), with FSs and full-field-of-view CBCT were included. Two different reference systems on the same FS were constructed. To assess validity, the two reference systems based on FSs were compared with the reference systems built using the CBCT scans. After two weeks, all of the FSs were reassessed to evaluate intra-operator repeatability. Reliability and repeatability were evaluated by means of parametric and non-parametric tests, intra-class correlation, the Dahlberg formula, and Bland–Altman plots (p < 0.05). Results: Both reference systems presented good reliability and showed a small difference with respect to the CBCT-based sagittal plane (Sagittal FS1 = 1.90 ± 0.98°; Sagittal FS2 = 1.80 ± 1.13°; p = 0.232). Between them, the two reference systems showed a small difference in the position of the sagittal plane (Sagittal FS1^Sagittal FS2 = 1.39 ± 1.13°). Conclusions: Both reference systems assessed in this study showed good intra-operator repeatability and their use may be suggested as reliable reference systems for FSs.

Validity and Reliability of New Three-Dimensional Reference Systems for Soft Tissue Analysis Using Non-Ionizing Three-Dimensional Imaging / Rongo, Roberto; D'Antò, Vincenzo; Michelotti, Ambrosina; Cornelis, Marie A.; Cattaneo, Paolo M.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 14:12(2024). [10.3390/app14125307]

Validity and Reliability of New Three-Dimensional Reference Systems for Soft Tissue Analysis Using Non-Ionizing Three-Dimensional Imaging

Roberto Rongo;Vincenzo D'Antò;Ambrosina Michelotti;
2024

Abstract

Featured Application: The use of a new and valid reference system for analysis of facial scans might improve the quality of the assessment of orthodontics and orthognathic outcomes. Background: The aim of this study was to evaluate the accuracy and the repeatability of two reference systems for three-dimensional facial scans (FSs) compared with a reference system based on cone-beam computed tomography (CBCT). Subjects and methods: A total of sixty subjects, thirty growing participants (8–17 years old) and thirty non-growing participants (older than 21 years old), with FSs and full-field-of-view CBCT were included. Two different reference systems on the same FS were constructed. To assess validity, the two reference systems based on FSs were compared with the reference systems built using the CBCT scans. After two weeks, all of the FSs were reassessed to evaluate intra-operator repeatability. Reliability and repeatability were evaluated by means of parametric and non-parametric tests, intra-class correlation, the Dahlberg formula, and Bland–Altman plots (p < 0.05). Results: Both reference systems presented good reliability and showed a small difference with respect to the CBCT-based sagittal plane (Sagittal FS1 = 1.90 ± 0.98°; Sagittal FS2 = 1.80 ± 1.13°; p = 0.232). Between them, the two reference systems showed a small difference in the position of the sagittal plane (Sagittal FS1^Sagittal FS2 = 1.39 ± 1.13°). Conclusions: Both reference systems assessed in this study showed good intra-operator repeatability and their use may be suggested as reliable reference systems for FSs.
2024
Validity and Reliability of New Three-Dimensional Reference Systems for Soft Tissue Analysis Using Non-Ionizing Three-Dimensional Imaging / Rongo, Roberto; D'Antò, Vincenzo; Michelotti, Ambrosina; Cornelis, Marie A.; Cattaneo, Paolo M.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 14:12(2024). [10.3390/app14125307]
File in questo prodotto:
File Dimensione Formato  
applsci-14-05307-v2.pdf

accesso aperto

Licenza: Dominio pubblico
Dimensione 2.78 MB
Formato Adobe PDF
2.78 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/993422
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact