Objectives To describe the new semisynthetic total ossicular replacement prosthesis (New-SSTORP) and to evaluate the New-SSTORP ossiculoplasty results both with the presence and absence of the stapes superstructure. Study Design Prospective study. Setting Tertiary referral center. Methods From April 2023 to May 2023, 18 New-SSTORP ossiculoplasties were performed by the first author. In all patients, the New-SSTORP was interposed between the footplate and the eardrum. The study group was divided into two groups (group A and group B). Group A included 13 patients with the absence of stapes superstructure. Group B included five patients with the presence of stapes superstructure. A successful reconstruction was defined as a postoperative air-bone gap ABG ≤20 dB. For all patients of groups A and B, the last audiometric control considered was performed in January 2024. The mean follow-up was 8½ months. The χ2 test was used to compare results. p < 0.05 was considered significant. Main Outcome Measures Mean postoperative ABG ≤20 dB Results At the end of follow-up, the overall success rate (ABG ≤20 dB) of New-SSTORP ossiculoplasty was obtained in 88.8% (n = 16 of 18) of cases. In group A, the success rate of New-SSTORP ossiculoplasty occurred in 84.6% (n = 11 of 13) of cases, and in group B, the success rate of New-SSTORP ossiculoplasty occurred in 100% (n = 5 of 5) of cases. There was no audiological statistically significant difference between groups A and B (Fisher value is 1; p < 0.05). In all cases, the time for positioning of New-SSTORP was about 5 minutes Conclusion The New-SSTORP has a minimal technical challenge for building and placement. The New-SSTORP ossiculoplasty results are very good both with the presence and absence of SS.
The New Semisynthetic TORP: A Prosthesis for Ossicular Reconstruction Both With the Absence and the Presence of the Stapes Superstructure / Malafronte, Giuseppe; Fetoni, Anna Rita; Motta, Gaetano; Presutti, Livio. - In: OTOLOGY & NEUROLOGY. - ISSN 1537-4505. - 45:7(2024), pp. 783-789. [10.1097/mao.0000000000004244]
The New Semisynthetic TORP: A Prosthesis for Ossicular Reconstruction Both With the Absence and the Presence of the Stapes Superstructure
Malafronte, Giuseppe
;Fetoni, Anna Rita;Motta, Gaetano;
2024
Abstract
Objectives To describe the new semisynthetic total ossicular replacement prosthesis (New-SSTORP) and to evaluate the New-SSTORP ossiculoplasty results both with the presence and absence of the stapes superstructure. Study Design Prospective study. Setting Tertiary referral center. Methods From April 2023 to May 2023, 18 New-SSTORP ossiculoplasties were performed by the first author. In all patients, the New-SSTORP was interposed between the footplate and the eardrum. The study group was divided into two groups (group A and group B). Group A included 13 patients with the absence of stapes superstructure. Group B included five patients with the presence of stapes superstructure. A successful reconstruction was defined as a postoperative air-bone gap ABG ≤20 dB. For all patients of groups A and B, the last audiometric control considered was performed in January 2024. The mean follow-up was 8½ months. The χ2 test was used to compare results. p < 0.05 was considered significant. Main Outcome Measures Mean postoperative ABG ≤20 dB Results At the end of follow-up, the overall success rate (ABG ≤20 dB) of New-SSTORP ossiculoplasty was obtained in 88.8% (n = 16 of 18) of cases. In group A, the success rate of New-SSTORP ossiculoplasty occurred in 84.6% (n = 11 of 13) of cases, and in group B, the success rate of New-SSTORP ossiculoplasty occurred in 100% (n = 5 of 5) of cases. There was no audiological statistically significant difference between groups A and B (Fisher value is 1; p < 0.05). In all cases, the time for positioning of New-SSTORP was about 5 minutes Conclusion The New-SSTORP has a minimal technical challenge for building and placement. The New-SSTORP ossiculoplasty results are very good both with the presence and absence of SS.| File | Dimensione | Formato | |
|---|---|---|---|
|
Malafronte et al., 2024 Otology & Neurotology.pdf
accesso aperto
Licenza:
Creative commons
Dimensione
389.91 kB
Formato
Adobe PDF
|
389.91 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


