Background: The aim of this study was to investigate 8-mm robotic trocar site hernia (TSH) rate over the short and long term, providing aids to manage the related fascial wounds. Methods: A retrospective analysis of 320 patients undergoing robotic surgery was conducted. The primary outcome was 8-mm TSH rate with a minimum follow-up of 12 months. The secondary outcome was the rate of haematomas and infections related to 8-mm wounds and their association with patient comorbidities and trocar position. Results: One case of TSH was observed (0.31%). There were 15 cases of wound infection (4.68%) and 22 cases of wound haematoma (6.87%). Trocar related complications were significantly associated with patient comorbidities, not with trocar position. Conclusions: Our results do not justify the 8-mm fascial wound closure. Data concerning the association between trocar-related complications and patient comorbidities strengthen the need to implement the control of metabolic state and correct administration of perioperative therapy in high-risk patients.

Robotic 8-mm trocar fascial wounds: To close or not to close? / Milone, M.; Anoldo, P.; Manigrasso, M.; Cantore, G.; Campanile, S.; Rompianesi, G.; Troisi, R. I.; D'Amore, A.; De Palma, G. D.. - In: THE INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY. - ISSN 1478-5951. - 20:2(2024). [10.1002/rcs.2624]

Robotic 8-mm trocar fascial wounds: To close or not to close?

Anoldo P.;Manigrasso M.;Cantore G.;Rompianesi G.;Troisi R. I.;De Palma G. D.
2024

Abstract

Background: The aim of this study was to investigate 8-mm robotic trocar site hernia (TSH) rate over the short and long term, providing aids to manage the related fascial wounds. Methods: A retrospective analysis of 320 patients undergoing robotic surgery was conducted. The primary outcome was 8-mm TSH rate with a minimum follow-up of 12 months. The secondary outcome was the rate of haematomas and infections related to 8-mm wounds and their association with patient comorbidities and trocar position. Results: One case of TSH was observed (0.31%). There were 15 cases of wound infection (4.68%) and 22 cases of wound haematoma (6.87%). Trocar related complications were significantly associated with patient comorbidities, not with trocar position. Conclusions: Our results do not justify the 8-mm fascial wound closure. Data concerning the association between trocar-related complications and patient comorbidities strengthen the need to implement the control of metabolic state and correct administration of perioperative therapy in high-risk patients.
2024
Robotic 8-mm trocar fascial wounds: To close or not to close? / Milone, M.; Anoldo, P.; Manigrasso, M.; Cantore, G.; Campanile, S.; Rompianesi, G.; Troisi, R. I.; D'Amore, A.; De Palma, G. D.. - In: THE INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY. - ISSN 1478-5951. - 20:2(2024). [10.1002/rcs.2624]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/974808
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact