A new bio-prosthetic valved conduit (Bio-Valsalva™) has recently been introduced into surgical practice in order to offer a valid option for elderly patients undergoing composite aortic root replacement. The conduit is made up of a stentless porcine valve (elan valve) presewn inside a triple layer Valsalva prosthesis and it is entirely preserved in a glutaraldehyde solution. In our Department, 21 patients (16 males, mean age 67.8±5.5 years) underwent aortic root replacement using the Bio-Valsalva™ prosthesis. Composite root replacement was extended to the hemiarch in three cases while a complete arch replacement was performed in two patients. Type A aortic dissection was present in two cases while a bicuspid aortic valve was detected in eight patients. In-hospital mortality was 4.7% (1 patient). Re-thoracotomy for bleeding was performed in one case. The median in-hospital stay was 12 days. The median follow-up was six months and is 100% complete. There were no re-operations or structural deterioration during this early phase of observation. The Bio-Valsalva™ graft, readily available in different sizes, demonstrates ease of implantability and shows good haemostatic characteristics. More patients and a longer follow-up are necessary to confirm the advantages of this graft. © 2008 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

Bio-Valsalva™ prosthesis: 'New' conduit for 'old' patients / Di Bartolomeo, R.; Botta, L.; Leone, A.; Pilato, E.; Martin-Suarez, S.; Bacchini, M.; Pacini, D.. - In: INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY. - ISSN 1569-9293. - 7:6(2008), pp. 1062-1066. [10.1510/icvts.2008.187849]

Bio-Valsalva™ prosthesis: 'New' conduit for 'old' patients

Pilato E.;
2008

Abstract

A new bio-prosthetic valved conduit (Bio-Valsalva™) has recently been introduced into surgical practice in order to offer a valid option for elderly patients undergoing composite aortic root replacement. The conduit is made up of a stentless porcine valve (elan valve) presewn inside a triple layer Valsalva prosthesis and it is entirely preserved in a glutaraldehyde solution. In our Department, 21 patients (16 males, mean age 67.8±5.5 years) underwent aortic root replacement using the Bio-Valsalva™ prosthesis. Composite root replacement was extended to the hemiarch in three cases while a complete arch replacement was performed in two patients. Type A aortic dissection was present in two cases while a bicuspid aortic valve was detected in eight patients. In-hospital mortality was 4.7% (1 patient). Re-thoracotomy for bleeding was performed in one case. The median in-hospital stay was 12 days. The median follow-up was six months and is 100% complete. There were no re-operations or structural deterioration during this early phase of observation. The Bio-Valsalva™ graft, readily available in different sizes, demonstrates ease of implantability and shows good haemostatic characteristics. More patients and a longer follow-up are necessary to confirm the advantages of this graft. © 2008 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.
2008
Bio-Valsalva™ prosthesis: 'New' conduit for 'old' patients / Di Bartolomeo, R.; Botta, L.; Leone, A.; Pilato, E.; Martin-Suarez, S.; Bacchini, M.; Pacini, D.. - In: INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY. - ISSN 1569-9293. - 7:6(2008), pp. 1062-1066. [10.1510/icvts.2008.187849]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/963990
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? ND
social impact