: Background: Recent reports have evidenced an increased mortality rate in hypertensive patients with electrocardiographic left ventricular hypertrophy (ECG-LVH) achieving systolic blood pressure (SBP) <130mmHg. However, to the best of our knowledge, the actual effects of BP reduction to the {less than or equal to}130/80mmHg target on the incidence of cardiovascular events in hypertensive patients with a diagnosis of LVH based on echocardiographic-criteria (Echo-LVH) have never been determined. Methods: In order to fill this long-standing knowledge gap, we harnessed a population of 9511 hypertensive patients, followed-up for 33.6 [IQR 7.9-72.7] months. The population was divided into six groups according to the average SBP achieved during the follow-up ({less than or equal to}130, 130-to-139, and {greater than or equal to}140mmHg) and absence/presence of Echo-LVH. The primary endpoint was a composite of fatal or non-fatal myocardial infarction and stroke, sudden cardiac death, heart failure requiring hospitalization, revascularization, and carotid stenting. Secondary endpoints included atrial fibrillation and transient ischemic attack. Results: During the follow-up, achieved SBP and diastolic BP (DBP) were comparable between patients with and without Echo-LVH. Strikingly, the rate of primary and secondary endpoints was significantly higher in patients with Echo-LVH and SBP>130mmHg, reaching the highest rate in the Echo-LVH group with SBP{greater than or equal to}140mmHg. By separate Cox multivariable regressions, after adjusting for potential confounders, both primary and secondary endpoints were significantly associated with SBP{greater than or equal to}140mmHg and Echo-LVH. Instead, DBP reduction {less than or equal to}80mmHg was associated with a significant increased rate of secondary events. Conclusions: In hypertensive patients with Echo-LVH, achieving an average in-treatment SBP target {less than or equal to}130mmHg has a beneficial prognostic impact on incidence of cardiovascular events. Significance Statement In contrast with recent reports, achieving in-treatment SBP≤130mmHg reduces the incidence of CV events in hypertensive patients with Echo-LVH. Reducing DBP≤80mmHg is instead associated with a higher rate of CV complications. By Cox multivariable regression models, adjusting for potential confounders, the rate of hard and soft CV events was significantly associated with Echo-LVH and SBP≥140mmHg. Our data indicate that therapeutic strategies in patients with Echo-LVH should aim at reducing SBP≤130mmHg paying attention to not reducing DBP≤80mmHg.

Achieving a Systolic Blood Pressure Below 130 mmHg Reduces the Incidence of Cardiovascular Events in Hypertensive Patients with Echocardiographic Left Ventricular Hypertrophy / Lembo, Maria; Trimarco, Valentina; Izzo, Raffaele; Manzi, Maria Virginia; Rozza, Francesco; Gallo, Paola; Morisco, Carmine; Bardi, Luca; Esposito, Giovanni; Forzano, Imma; Santulli, Gaetano; Trimarco, Bruno. - In: THE JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS. - ISSN 1521-0103. - (2023). [10.1124/jpet.123.001952]

Achieving a Systolic Blood Pressure Below 130 mmHg Reduces the Incidence of Cardiovascular Events in Hypertensive Patients with Echocardiographic Left Ventricular Hypertrophy

Lembo, Maria;Trimarco, Valentina;Izzo, Raffaele;Manzi, Maria Virginia;Rozza, Francesco;Gallo, Paola;Morisco, Carmine;Bardi, Luca;Esposito, Giovanni;Forzano, Imma;Santulli, Gaetano;Trimarco, Bruno
2023

Abstract

: Background: Recent reports have evidenced an increased mortality rate in hypertensive patients with electrocardiographic left ventricular hypertrophy (ECG-LVH) achieving systolic blood pressure (SBP) <130mmHg. However, to the best of our knowledge, the actual effects of BP reduction to the {less than or equal to}130/80mmHg target on the incidence of cardiovascular events in hypertensive patients with a diagnosis of LVH based on echocardiographic-criteria (Echo-LVH) have never been determined. Methods: In order to fill this long-standing knowledge gap, we harnessed a population of 9511 hypertensive patients, followed-up for 33.6 [IQR 7.9-72.7] months. The population was divided into six groups according to the average SBP achieved during the follow-up ({less than or equal to}130, 130-to-139, and {greater than or equal to}140mmHg) and absence/presence of Echo-LVH. The primary endpoint was a composite of fatal or non-fatal myocardial infarction and stroke, sudden cardiac death, heart failure requiring hospitalization, revascularization, and carotid stenting. Secondary endpoints included atrial fibrillation and transient ischemic attack. Results: During the follow-up, achieved SBP and diastolic BP (DBP) were comparable between patients with and without Echo-LVH. Strikingly, the rate of primary and secondary endpoints was significantly higher in patients with Echo-LVH and SBP>130mmHg, reaching the highest rate in the Echo-LVH group with SBP{greater than or equal to}140mmHg. By separate Cox multivariable regressions, after adjusting for potential confounders, both primary and secondary endpoints were significantly associated with SBP{greater than or equal to}140mmHg and Echo-LVH. Instead, DBP reduction {less than or equal to}80mmHg was associated with a significant increased rate of secondary events. Conclusions: In hypertensive patients with Echo-LVH, achieving an average in-treatment SBP target {less than or equal to}130mmHg has a beneficial prognostic impact on incidence of cardiovascular events. Significance Statement In contrast with recent reports, achieving in-treatment SBP≤130mmHg reduces the incidence of CV events in hypertensive patients with Echo-LVH. Reducing DBP≤80mmHg is instead associated with a higher rate of CV complications. By Cox multivariable regression models, adjusting for potential confounders, the rate of hard and soft CV events was significantly associated with Echo-LVH and SBP≥140mmHg. Our data indicate that therapeutic strategies in patients with Echo-LVH should aim at reducing SBP≤130mmHg paying attention to not reducing DBP≤80mmHg.
2023
Achieving a Systolic Blood Pressure Below 130 mmHg Reduces the Incidence of Cardiovascular Events in Hypertensive Patients with Echocardiographic Left Ventricular Hypertrophy / Lembo, Maria; Trimarco, Valentina; Izzo, Raffaele; Manzi, Maria Virginia; Rozza, Francesco; Gallo, Paola; Morisco, Carmine; Bardi, Luca; Esposito, Giovanni; Forzano, Imma; Santulli, Gaetano; Trimarco, Bruno. - In: THE JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS. - ISSN 1521-0103. - (2023). [10.1124/jpet.123.001952]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/948890
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact