The Banat seismic area in Romania is characterized by shallow earthquakes that generate in historic buildings different failure mechanisms. Religious buildings represent one of the most important historical buildings in Romania, with interesting structures and beautiful architectural details, but many of them in a poor conservation state. The failure mechanisms of the historical Romanian Baroque churches recorded after the earthquakes of 1990 and 1991 are due to the high value of the vertical components of the seismic action, the reduced number of cycles. The article presents the values of the seismic risk factor determined for three churches: Chizatau, Beregsau Mare and Birda churches with the ETABS software according to the Romanian design code P100-3 / 2019 in which the effects of the vertical seismic components are not taken into analysis.

Seismic Assessment of Typical Historical Masonry Churches in Banat region, Romania - Part I / Monaco, A. L.; Grillanda, N.; Onescu, I.; Fofiu, M.; Clementi, F.; D'Amato, M.; Formisano, A.; Milani, G.; Mosoarca, M.. - In: PROCEDIA STRUCTURAL INTEGRITY. - ISSN 2452-3216. - 44:(2022), pp. 2058-2065. (Intervento presentato al convegno 19th ANIDIS Conference, Seismic Engineering in Italy tenutosi a ita nel 2022) [10.1016/j.prostr.2023.01.263].

Seismic Assessment of Typical Historical Masonry Churches in Banat region, Romania - Part I

Formisano A.;
2022

Abstract

The Banat seismic area in Romania is characterized by shallow earthquakes that generate in historic buildings different failure mechanisms. Religious buildings represent one of the most important historical buildings in Romania, with interesting structures and beautiful architectural details, but many of them in a poor conservation state. The failure mechanisms of the historical Romanian Baroque churches recorded after the earthquakes of 1990 and 1991 are due to the high value of the vertical components of the seismic action, the reduced number of cycles. The article presents the values of the seismic risk factor determined for three churches: Chizatau, Beregsau Mare and Birda churches with the ETABS software according to the Romanian design code P100-3 / 2019 in which the effects of the vertical seismic components are not taken into analysis.
2022
Seismic Assessment of Typical Historical Masonry Churches in Banat region, Romania - Part I / Monaco, A. L.; Grillanda, N.; Onescu, I.; Fofiu, M.; Clementi, F.; D'Amato, M.; Formisano, A.; Milani, G.; Mosoarca, M.. - In: PROCEDIA STRUCTURAL INTEGRITY. - ISSN 2452-3216. - 44:(2022), pp. 2058-2065. (Intervento presentato al convegno 19th ANIDIS Conference, Seismic Engineering in Italy tenutosi a ita nel 2022) [10.1016/j.prostr.2023.01.263].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/948803
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact