This paper aims to show some results of seismic assessment of Romanian Orthodox existing masonry churches, by extending the multi-level approach proposed by the Italian directive for seismic risk evaluation of cultural heritage. To this scope, a sample of six existing churches is examined, belonging to a church typology characterized by a single vaulted nave and a bell tower incorporated into the main façade. All churches considered in this study are located in the Banat region, which is an area with a medium–high seismic hazard. Firstly, territorial Level of Valuations (LV0 and LV1) are conducted on the churches sample examined. Afterwards, local (LV2) and global (LV3) valuations are performed on a case study, the Învierea Domnului church, assumed representative of all the churches sample under consideration. In particular, local analyses are performed on some church architectural portions with the kinematic limit analysis. Whereas, global analyses are conducted with non-linear push-over approach. Comments and comparisons of the obtained results are reported for each LV examined.

Seismic assessment of Romanian Orthodox masonry churches in the Banat area through a multi-level analysis framework / Lo Monaco, A.; Grillanda, N.; Onescu, I.; Fofiu, M.; Clementi, F.; D'Amato, M.; Formisano, A.; Milani, G.; Mosoarca, M.. - In: ENGINEERING FAILURE ANALYSIS. - ISSN 1350-6307. - 153:(2023), pp. 1-29. [10.1016/j.engfailanal.2023.107539]

Seismic assessment of Romanian Orthodox masonry churches in the Banat area through a multi-level analysis framework

Formisano A.;
2023

Abstract

This paper aims to show some results of seismic assessment of Romanian Orthodox existing masonry churches, by extending the multi-level approach proposed by the Italian directive for seismic risk evaluation of cultural heritage. To this scope, a sample of six existing churches is examined, belonging to a church typology characterized by a single vaulted nave and a bell tower incorporated into the main façade. All churches considered in this study are located in the Banat region, which is an area with a medium–high seismic hazard. Firstly, territorial Level of Valuations (LV0 and LV1) are conducted on the churches sample examined. Afterwards, local (LV2) and global (LV3) valuations are performed on a case study, the Învierea Domnului church, assumed representative of all the churches sample under consideration. In particular, local analyses are performed on some church architectural portions with the kinematic limit analysis. Whereas, global analyses are conducted with non-linear push-over approach. Comments and comparisons of the obtained results are reported for each LV examined.
2023
Seismic assessment of Romanian Orthodox masonry churches in the Banat area through a multi-level analysis framework / Lo Monaco, A.; Grillanda, N.; Onescu, I.; Fofiu, M.; Clementi, F.; D'Amato, M.; Formisano, A.; Milani, G.; Mosoarca, M.. - In: ENGINEERING FAILURE ANALYSIS. - ISSN 1350-6307. - 153:(2023), pp. 1-29. [10.1016/j.engfailanal.2023.107539]
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1350630723004934-main_compressed.pdf

accesso aperto

Licenza: Creative commons
Dimensione 1.53 MB
Formato Adobe PDF
1.53 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/948670
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact