Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
Using the entire data sample of 980 fb-1 collected at or near the ϒ(4S) resonance with the Belle detector operating at the KEKB asymmetric-energy e+e- collider, we report the measurement of the mass, width, and the branching ratios of the Λc(2625)+ charmed baryon. The mass difference between Λc(2625)+ and Λc+ is measured to be M(Λc(2625)+)-M(Λc+)=341.518±0.006±0.049 MeV/c2. The upper limit on the width is measured to be Γ(Λc(2625)+)<0.52 MeV/c2 at 90% confidence level. Based on a full Dalitz plot fit, branching ratios with respect to the mode Λc(2625)+→Λc+π+π- are measured to be B(Λc(2625)+→Σc0π+)B(Λc(2625)+→Λc+π+π-)=(5.19±0.23±0.40)% and B(Λc(2625)+→Σc++π-)B(Λc(2625)+→Λc+π+π-)=(5.13±0.26±0.32)%, where the first and second uncertainties are statistical and systematic, respectively. These measurements can be used to further constrain the parameters of the underlying theoretical models.
Measurement of the mass and width of the Λc (2625)+ charmed baryon and the branching ratios of Λc (2625)+ → Σc0 π+ and Λc (2625)+ → Σc+ + π- / Wang, D.; Yelton, J.; Adachi, I.; Ahn, J. K.; Aihara, H.; Asner, D. M.; Atmacan, H.; Ayad, R.; Babu, V.; Banerjee, S.; Bauer, M.; Behera, P.; Belous, K.; Bennett, J.; Bessner, M.; Bilka, T.; Biswas, D.; Bodrov, D.; Borah, J.; Bozek, A.; Bracko, M.; Branchini, P.; Browder, T. E.; Budano, A.; Campajola, M.; Cervenkov, D.; Chang, M. -C.; Chen, A.; Cheon, B. G.; Cho, H. E.; Cho, K.; Cho, S. -J.; Choi, S. -K.; Choi, Y.; Choudhury, S.; Cinabro, D.; Das, S.; De Nardo, G.; De Pietro, G.; Dhamija, R.; Di Capua, F.; Dolezal, Z.; Dong, T. V.; Dossett, D.; Epifanov, D.; Ferber, T.; Ferlewicz, D.; Fulsom, B. G.; Garg, R.; Gaur, V.; Giri, A.; Goldenzweig, P.; Graziani, E.; Gu, T.; Gudkova, K.; Hadjivasiliou, C.; Han, X.; Hayasaka, K.; Hayashii, H.; Hedges, M. T.; Hsu, C. -L.; Inami, K.; Ipsita, N.; Ishikawa, A.; Itoh, R.; Iwasaki, M.; Jacobs, W. W.; Jang, E. -J.; Jia, S.; Jin, Y.; Kaliyar, A. B.; Kang, K. H.; Kawasaki, T.; Kiesling, C.; Kim, C. H.; Kim, D. Y.; Kim, K. -H.; Kim, Y. -K.; Kinoshita, K.; Kodys, P.; Korobov, A.; Korpar, S.; Kovalenko, E.; Krizan, P.; Krokovny, P.; Kumar, M.; Kumar, R.; Kumara, K.; Kwon, Y. -J.; Lam, T.; Lange, J. S.; Lee, S. C.; Levit, D.; Lewis, P.; Li, L. K.; Li, Y.; Li, Y. B.; Li Gioi, L.; Libby, J.; Lieret, K.; Lin, Y. -R.; Liventsev, D.; Matsuda, T.; Matvienko, D.; Meier, F.; Merola, M.; Metzner, F.; Miyabayashi, K.; Mizuk, R.; Mohanty, G. B.; Mussa, R.; Nakamura, I.; Nakano, T.; Nakao, M.; Natkaniec, Z.; Natochii, A.; Nayak, L.; Nayak, M.; Nisar, N. K.; Nishida, S.; Ogawa, S.; Ono, H.; Oskin, P.; Pakhlova, G.; Pardi, S.; Park, H.; Park, J.; Patra, S.; Paul, S.; Pedlar, T. K.; Pestotnik, R.; Piilonen, L. E.; Podobnik, T.; Prencipe, E.; Prim, M. T.; Rout, N.; Russo, G.; Sandilya, S.; Sangal, A.; Santelj, L.; Savinov, V.; Schnell, G.; Schueler, J.; Schwanda, C.; Seino, Y.; Senyo, K.; Sevior, M. E.; Shan, W.; Shapkin, M.; Sharma, C.; Shen, C. P.; Shiu, J. -G.; Sokolov, A.; Solovieva, E.; Staric, M.; Sumihama, M.; Sumiyoshi, T.; Sutcliffe, W.; Takizawa, M.; Tamponi, U.; Tanida, K.; Tenchini, F.; Uchida, M.; Uno, S.; Van Tonder, R.; Varner, G.; Varvell, K. E.; Vinokurova, A.; Wang, M. -Z.; Wang, X. L.; Watanabe, M.; Watanuki, S.; Werbycka, O.; Won, E.; Xu, X.; Yabsley, B. D.; Yan, W.; Yang, S. B.; Yin, J. H.; Yuan, C. Z.; Yuan, L.; Zhang, Z. P.; Zhilich, V.; Zhukova, V.. - In: PHYSICAL REVIEW D. - ISSN 2470-0010. - 107:3(2023). [10.1103/PhysRevD.107.032008]
Measurement of the mass and width of the Λc (2625)+ charmed baryon and the branching ratios of Λc (2625)+ → Σc0 π+ and Λc (2625)+ → Σc+ + π-
Wang D.;Yelton J.;Adachi I.;Ahn J. K.;Aihara H.;Asner D. M.;Atmacan H.;Ayad R.;Babu V.;Banerjee S.;Bauer M.;Behera P.;Belous K.;Bennett J.;Bessner M.;Bilka T.;Biswas D.;Bodrov D.;Borah J.;Bozek A.;Bracko M.;Branchini P.;Browder T. E.;Budano A.;Campajola M.;Cervenkov D.;Chang M. -C.;Chen A.;Cheon B. G.;Cho H. E.;Cho K.;Cho S. -J.;Choi S. -K.;Choi Y.;Choudhury S.;Cinabro D.;Das S.;De Nardo G.;De Pietro G.;Dhamija R.;Di Capua F.;DoleZal Z.;Dong T. V.;Dossett D.;Epifanov D.;Ferber T.;Ferlewicz D.;Fulsom B. G.;Garg R.;Gaur V.;Giri A.;Goldenzweig P.;Graziani E.;Gu T.;Gudkova K.;Hadjivasiliou C.;Han X.;Hayasaka K.;Hayashii H.;Hedges M. T.;Hsu C. -L.;Inami K.;Ipsita N.;Ishikawa A.;Itoh R.;Iwasaki M.;Jacobs W. W.;Jang E. -J.;Jia S.;Jin Y.;Kaliyar A. B.;Kang K. H.;Kawasaki T.;Kiesling C.;Kim C. H.;Kim D. Y.;Kim K. -H.;Kim Y. -K.;Kinoshita K.;Kodys P.;Korobov A.;Korpar S.;Kovalenko E.;KriZan P.;Krokovny P.;Kumar M.;Kumar R.;Kumara K.;Kwon Y. -J.;Lam T.;Lange J. S.;Lee S. C.;Levit D.;Lewis P.;Li L. K.;Li Y.;Li Y. B.;Li Gioi L.;Libby J.;Lieret K.;Lin Y. -R.;Liventsev D.;Matsuda T.;Matvienko D.;Meier F.;Merola M.;Metzner F.;Miyabayashi K.;Mizuk R.;Mohanty G. B.;Mussa R.;Nakamura I.;Nakano T.;Nakao M.;Natkaniec Z.;Natochii A.;Nayak L.;Nayak M.;Nisar N. K.;Nishida S.;Ogawa S.;Ono H.;Oskin P.;Pakhlova G.;Pardi S.;Park H.;Park J.;Patra S.;Paul S.;Pedlar T. K.;Pestotnik R.;Piilonen L. E.;Podobnik T.;Prencipe E.;Prim M. T.;Rout N.;Russo G.;Sandilya S.;Sangal A.;Santelj L.;Savinov V.;Schnell G.;Schueler J.;Schwanda C.;Seino Y.;Senyo K.;Sevior M. E.;Shan W.;Shapkin M.;Sharma C.;Shen C. P.;Shiu J. -G.;Sokolov A.;Solovieva E.;Staric M.;Sumihama M.;Sumiyoshi T.;Sutcliffe W.;Takizawa M.;Tamponi U.;Tanida K.;Tenchini F.;Uchida M.;Uno S.;Van Tonder R.;Varner G.;Varvell K. E.;Vinokurova A.;Wang M. -Z.;Wang X. L.;Watanabe M.;Watanuki S.;Werbycka O.;Won E.;Xu X.;Yabsley B. D.;Yan W.;Yang S. B.;Yin J. H.;Yuan C. Z.;Yuan L.;Zhang Z. P.;Zhilich V.;Zhukova V.
2023
Abstract
Using the entire data sample of 980 fb-1 collected at or near the ϒ(4S) resonance with the Belle detector operating at the KEKB asymmetric-energy e+e- collider, we report the measurement of the mass, width, and the branching ratios of the Λc(2625)+ charmed baryon. The mass difference between Λc(2625)+ and Λc+ is measured to be M(Λc(2625)+)-M(Λc+)=341.518±0.006±0.049 MeV/c2. The upper limit on the width is measured to be Γ(Λc(2625)+)<0.52 MeV/c2 at 90% confidence level. Based on a full Dalitz plot fit, branching ratios with respect to the mode Λc(2625)+→Λc+π+π- are measured to be B(Λc(2625)+→Σc0π+)B(Λc(2625)+→Λc+π+π-)=(5.19±0.23±0.40)% and B(Λc(2625)+→Σc++π-)B(Λc(2625)+→Λc+π+π-)=(5.13±0.26±0.32)%, where the first and second uncertainties are statistical and systematic, respectively. These measurements can be used to further constrain the parameters of the underlying theoretical models.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/938507
Citazioni
ND
0
0
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.