Objectives: This prospective study evaluated the accuracy of mandibular reconstruction using free fibular flaps (by comparing virtual plans to the three-dimensional postoperative results), and the extent of bone-to-bone contact after computer-assisted surgery. Methods: We included 65 patients who underwent partial-continuity mandibular resections from February 2013 to January 2017, and evaluated virtual planning, surgical techniques, and accuracy. Results: Forty-seven patients were analysed. A total of 112 fibular segments received 54 implants. We measured 227 distances between landmarks to assess the accuracy of reconstruction. Postoperative reconstruction accuracy ranged from 0.5 to 3 mm. Conclusion: Virtual surgical planning very accurately translated simulation into reality, particularly in patients requiring large, complex mandibular reconstructions using multiple fibular segments. Level of evidence: 4 Laryngoscope, 131:E2169–E2175, 2021.
Accuracy of Fibula Reconstruction Using Patient-Specific Cad/Cam Plates: A Multicenter Study on 47 Patients / Zavattero, E., Bolzoni, A., Dell'Aversana, G., Santagata, M., Massarelli, O., Ferri, A., Della Monaca, M., Copelli, C., Gessaroli, M., Valsecchi, S., Borbon, C., Beltramini, G.A., Ramieri, G., Valentini, V., Tartaro, G.P., Cocchi, R., Varazzani, A., Califano, L., Baj, A.. - In: LARYNGOSCOPE. - ISSN 0023-852X. - 1:7(2021), pp. E2169-E2175. [10.1002/lary.29379]
Accuracy of Fibula Reconstruction Using Patient-Specific Cad/Cam Plates: A Multicenter Study on 47 Patients
Valentini V.;Cocchi R.;
2021
Abstract
Objectives: This prospective study evaluated the accuracy of mandibular reconstruction using free fibular flaps (by comparing virtual plans to the three-dimensional postoperative results), and the extent of bone-to-bone contact after computer-assisted surgery. Methods: We included 65 patients who underwent partial-continuity mandibular resections from February 2013 to January 2017, and evaluated virtual planning, surgical techniques, and accuracy. Results: Forty-seven patients were analysed. A total of 112 fibular segments received 54 implants. We measured 227 distances between landmarks to assess the accuracy of reconstruction. Postoperative reconstruction accuracy ranged from 0.5 to 3 mm. Conclusion: Virtual surgical planning very accurately translated simulation into reality, particularly in patients requiring large, complex mandibular reconstructions using multiple fibular segments. Level of evidence: 4 Laryngoscope, 131:E2169–E2175, 2021.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


