OBJECTIVE: Recently, Zirconia and polyaryletherketone (PEEK) have attracted increasing interest as reliable and safe materials in dental applications, mainly because of their good biomechanical characteristics. The aim of this study was to investigate the response to different loads by prosthetic frameworks for supported fixed partial dentures (FPDs), thus simulating osseointegrated implants. MATERIALS AND METHODS: The specimens were divided into two groups (n= 5 each). Group A: FDPs in zirconia-ceramic; Group B: FDPs in PEEK-composite. These 2 groups were subjected to vertical loads so to evaluate structural deformation; then, they have been analyzed by scanning electron microscopy (SEM) at different magnifications. RESULTS: In tested samples, different types of mechanical failures have been observed. In Zirconia-specimens, chipping is the main failure noticed in this study, mostly in distal margins of the structure. Also, peek-specimens show failure and fracture. CONCLUSIONS: Zirconia and PEEK could be considered both good materials, but several investigations are needed to use these materials as an alternative to metals for fixed partial dentures.

In vitro comparative study on the mechanical behavior of Zirconia and Polyetheretherketone in applied dental sciences / Vertucci, V.; Pacifici, A.; Ruggiero, R.; Pacifici, L.; Amantea, M.; Marrelli, B.; Giacomello, M.; Valletta, A.; Riccitiello, F.; Greco Lucchina, A.; Mortellaro, C.; Rengo, S.; Sammartino, G.; Tatullo, M.. - In: EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES. - ISSN 2284-0729. - 26:3(2022), pp. 106-114. [10.26355/eurrev_202212_30800]

In vitro comparative study on the mechanical behavior of Zirconia and Polyetheretherketone in applied dental sciences

Pacifici A.;Valletta A.;Riccitiello F.;Rengo S.;Sammartino G.;
2022

Abstract

OBJECTIVE: Recently, Zirconia and polyaryletherketone (PEEK) have attracted increasing interest as reliable and safe materials in dental applications, mainly because of their good biomechanical characteristics. The aim of this study was to investigate the response to different loads by prosthetic frameworks for supported fixed partial dentures (FPDs), thus simulating osseointegrated implants. MATERIALS AND METHODS: The specimens were divided into two groups (n= 5 each). Group A: FDPs in zirconia-ceramic; Group B: FDPs in PEEK-composite. These 2 groups were subjected to vertical loads so to evaluate structural deformation; then, they have been analyzed by scanning electron microscopy (SEM) at different magnifications. RESULTS: In tested samples, different types of mechanical failures have been observed. In Zirconia-specimens, chipping is the main failure noticed in this study, mostly in distal margins of the structure. Also, peek-specimens show failure and fracture. CONCLUSIONS: Zirconia and PEEK could be considered both good materials, but several investigations are needed to use these materials as an alternative to metals for fixed partial dentures.
2022
In vitro comparative study on the mechanical behavior of Zirconia and Polyetheretherketone in applied dental sciences / Vertucci, V.; Pacifici, A.; Ruggiero, R.; Pacifici, L.; Amantea, M.; Marrelli, B.; Giacomello, M.; Valletta, A.; Riccitiello, F.; Greco Lucchina, A.; Mortellaro, C.; Rengo, S.; Sammartino, G.; Tatullo, M.. - In: EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES. - ISSN 2284-0729. - 26:3(2022), pp. 106-114. [10.26355/eurrev_202212_30800]
File in questo prodotto:
File Dimensione Formato  
106-114-1-3.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Copyright dell'editore
Dimensione 2.8 MB
Formato Adobe PDF
2.8 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/906868
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact