Background: 2D speckle tracking echocardiography (STE) atrial strain (ε) analysis in children is gaining interest; however, pediatric nomograms remain limited. Comparison among conventional software's (designed for left ventricle and adapted to atria and using R-gating analysis) and new software's (designed for atria and allowing for both R- and P-gating) are lacking. The present study aims to establish pediatric nomograms for atrial ε using an atrial dedicated software and to compare values obtained by (a) R- and P-gating and, (b) R-gating with new and conventional software. Methods: Echocardiographic measurements included STE left (LA) and right (RA) atrial longitudinal reservoir, conduit and contractile ε. Age/weigh/height/heart rate, and body surface area (BSA) were used as independent variables in the statistical analysis. Results: In all, 580 healthy subjects (age range, 31 days-18 years; mean age 7.5 years; median age 7.1 years; inter-quartile range, 4.3–10.7 months; 45.5% female) were included. Feasibility of atrial ε measurements was high (98.9–96.8%). At lower age, atrial conduit ε was lower (p<0.001) while contractile ε was higher (p<0.001). All atrial ε values calculated with P-gating method were lower—than R-gating values (p<0.001). R-gated LA ε reservoir values generated with the new software were lower, and R-gated RA contractile ε higher than with the conventional software (p<0.011). Conclusion: We report pediatric atrial ε values from a dedicated atrial software. Maturational changes in STE atrial ε values were demonstrated. Significant differences were observed among ε values obtained with P- and R-gating and with different software's.

Pediatric ranges of normality for 2D speckle-tracking echocardiography atrial strain: differences between p- and r-gating and among new (Atrial Designed) and conventional (Ventricular Specific) software's / Marchese, P.; Scalese, M.; Giordano, R.; Assanta, N.; Franchi, E.; Koestenberger, M.; Ravaglioli, A.; Kutty, S.; Cantinotti, M.. - In: ECHOCARDIOGRAPHY. - ISSN 0742-2822. - 38:12(2021), pp. 2025-2031. [10.1111/echo.15244]

Pediatric ranges of normality for 2D speckle-tracking echocardiography atrial strain: differences between p- and r-gating and among new (Atrial Designed) and conventional (Ventricular Specific) software's

Giordano R.
;
2021

Abstract

Background: 2D speckle tracking echocardiography (STE) atrial strain (ε) analysis in children is gaining interest; however, pediatric nomograms remain limited. Comparison among conventional software's (designed for left ventricle and adapted to atria and using R-gating analysis) and new software's (designed for atria and allowing for both R- and P-gating) are lacking. The present study aims to establish pediatric nomograms for atrial ε using an atrial dedicated software and to compare values obtained by (a) R- and P-gating and, (b) R-gating with new and conventional software. Methods: Echocardiographic measurements included STE left (LA) and right (RA) atrial longitudinal reservoir, conduit and contractile ε. Age/weigh/height/heart rate, and body surface area (BSA) were used as independent variables in the statistical analysis. Results: In all, 580 healthy subjects (age range, 31 days-18 years; mean age 7.5 years; median age 7.1 years; inter-quartile range, 4.3–10.7 months; 45.5% female) were included. Feasibility of atrial ε measurements was high (98.9–96.8%). At lower age, atrial conduit ε was lower (p<0.001) while contractile ε was higher (p<0.001). All atrial ε values calculated with P-gating method were lower—than R-gating values (p<0.001). R-gated LA ε reservoir values generated with the new software were lower, and R-gated RA contractile ε higher than with the conventional software (p<0.011). Conclusion: We report pediatric atrial ε values from a dedicated atrial software. Maturational changes in STE atrial ε values were demonstrated. Significant differences were observed among ε values obtained with P- and R-gating and with different software's.
2021
Pediatric ranges of normality for 2D speckle-tracking echocardiography atrial strain: differences between p- and r-gating and among new (Atrial Designed) and conventional (Ventricular Specific) software's / Marchese, P.; Scalese, M.; Giordano, R.; Assanta, N.; Franchi, E.; Koestenberger, M.; Ravaglioli, A.; Kutty, S.; Cantinotti, M.. - In: ECHOCARDIOGRAPHY. - ISSN 0742-2822. - 38:12(2021), pp. 2025-2031. [10.1111/echo.15244]
File in questo prodotto:
File Dimensione Formato  
77 Pediatric range Echocardiography .pdf

solo utenti autorizzati

Licenza: Accesso privato/ristretto
Dimensione 1.68 MB
Formato Adobe PDF
1.68 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/899265
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact