We measured the surface tension of linear alkylbenzene (LAB) HYBLENE 113 mixed with Diphenyloxazole (PPO) as well as of pure LAB HYBLENE 113 as part of material studies for the liquid-scintillator based surround background tagger (SBT) in the proposed SHiP experiment. The measurement was performed using the iron wire method and the surface tension for linear alkyl benzene HYBLENE 113 plus PPO was found to be (30.0 ± 0.6) mN/m 22.0 ± 0.5°C and for pure HYBLENE 113,(29.2 ± 0.6) mN/m at 21.0 ± 0.5°C.

First measurement of the surface tension of a liquid scintillator based on Linear Alkylbenzene (HYBLENE 113) / Alt, J.; Arutinov, D.; Bezshyyko, O.; Bretz, T.; Brignoli, A.; Conaboy, A.; Deucher, P.; De Paola, F.; del Giudice, G.; di Cristo, C.; Fecarotta, O.; Fiorillo, A.; Fischer, H.; Glückler, H.; Grewing, C.; Hollnagel, A.; Lacker, H.; Miano, A.; Natour, G.; Orlov, V.; Prota, A.; Rehbein, F.; Reghunath, A.; Salzano, A.; Schaaf, M.; Scharf, C.; Schmidt, J.; Schumann, M.; Vagts, A.; van Waasen, S.; Wurm, M.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 17:05(2022), p. T05012. [10.1088/1748-0221/17/05/t05012]

First measurement of the surface tension of a liquid scintillator based on Linear Alkylbenzene (HYBLENE 113)

De Paola, F.;del Giudice, G.;di Cristo, C.;Fecarotta, O.;Fiorillo, A.;Miano, A.;Prota, A.;Salzano, A.;
2022

Abstract

We measured the surface tension of linear alkylbenzene (LAB) HYBLENE 113 mixed with Diphenyloxazole (PPO) as well as of pure LAB HYBLENE 113 as part of material studies for the liquid-scintillator based surround background tagger (SBT) in the proposed SHiP experiment. The measurement was performed using the iron wire method and the surface tension for linear alkyl benzene HYBLENE 113 plus PPO was found to be (30.0 ± 0.6) mN/m 22.0 ± 0.5°C and for pure HYBLENE 113,(29.2 ± 0.6) mN/m at 21.0 ± 0.5°C.
2022
First measurement of the surface tension of a liquid scintillator based on Linear Alkylbenzene (HYBLENE 113) / Alt, J.; Arutinov, D.; Bezshyyko, O.; Bretz, T.; Brignoli, A.; Conaboy, A.; Deucher, P.; De Paola, F.; del Giudice, G.; di Cristo, C.; Fecarotta, O.; Fiorillo, A.; Fischer, H.; Glückler, H.; Grewing, C.; Hollnagel, A.; Lacker, H.; Miano, A.; Natour, G.; Orlov, V.; Prota, A.; Rehbein, F.; Reghunath, A.; Salzano, A.; Schaaf, M.; Scharf, C.; Schmidt, J.; Schumann, M.; Vagts, A.; van Waasen, S.; Wurm, M.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 17:05(2022), p. T05012. [10.1088/1748-0221/17/05/t05012]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/954283
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact