This paper compares the metrological performance of a sample of commercial domestic/residential smart meters for natural gas (G4). In particular, the performance degradation of electronic static and dynamic gas meters has been evaluated. The sample was composed by ultrasonic gas meters, thermal mass meters and diaphragm gas meters. The tests, performed on the gas meters, reproduce the most severe operating conditions (i.e. filed test) such as the influence of the gas composition, the temperature difference between gas and meter, the gas humidity and the presence of dust in the gas. Furthermore, the meters have been undergo to some endurance tests such as start and stop and to the high flowrate runs.

Experimental Assessment of Gas Static Meters under Different Operating Conditions / Cascetta, F.; Bondesan, M.; Musto, M.; Rotondo, G.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 1868:1(2021), p. 012012. (Intervento presentato al convegno 2020 Italian Union of Thermo-Fluid Dynamics Seminar on Heat Transfer, UIT-HTS 2020 tenutosi a ita nel 2020) [10.1088/1742-6596/1868/1/012012].

Experimental Assessment of Gas Static Meters under Different Operating Conditions

Cascetta F.;Musto M.
;
Rotondo G.
2021

Abstract

This paper compares the metrological performance of a sample of commercial domestic/residential smart meters for natural gas (G4). In particular, the performance degradation of electronic static and dynamic gas meters has been evaluated. The sample was composed by ultrasonic gas meters, thermal mass meters and diaphragm gas meters. The tests, performed on the gas meters, reproduce the most severe operating conditions (i.e. filed test) such as the influence of the gas composition, the temperature difference between gas and meter, the gas humidity and the presence of dust in the gas. Furthermore, the meters have been undergo to some endurance tests such as start and stop and to the high flowrate runs.
2021
Experimental Assessment of Gas Static Meters under Different Operating Conditions / Cascetta, F.; Bondesan, M.; Musto, M.; Rotondo, G.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 1868:1(2021), p. 012012. (Intervento presentato al convegno 2020 Italian Union of Thermo-Fluid Dynamics Seminar on Heat Transfer, UIT-HTS 2020 tenutosi a ita nel 2020) [10.1088/1742-6596/1868/1/012012].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/860863
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact