This paper describes the operating and technical details of the practical implementation of an innovative time domain reflectometry (TDR)-system for monitoring rising damp in building structures. The proposed system employs wire-like, passive, diffused sensing elements (SE's) that are embedded, at the time of construction or renovation, inside the walls of the building to be monitored. The SE's remain permanently inside the wall, ready to be interrogated when necessary.
Practical implementation of diffused sensing elements for TDR-based monitoring of rising damp in building structures / Cataldo, Andrea; De Benedetto, E.; Cannazza, G.; Piuzzi, E.. - (2015), pp. 1167-1170. (Intervento presentato al convegno 21st IMEKO World Congress on Measurement in Research and Industry tenutosi a Prague, cze nel 2015).
Practical implementation of diffused sensing elements for TDR-based monitoring of rising damp in building structures
De Benedetto E.;
2015
Abstract
This paper describes the operating and technical details of the practical implementation of an innovative time domain reflectometry (TDR)-system for monitoring rising damp in building structures. The proposed system employs wire-like, passive, diffused sensing elements (SE's) that are embedded, at the time of construction or renovation, inside the walls of the building to be monitored. The SE's remain permanently inside the wall, ready to be interrogated when necessary.File | Dimensione | Formato | |
---|---|---|---|
IMEKO-WC-2015-TC10-235.pdf
accesso aperto
Descrizione: paper pubblicato
Tipologia:
Versione Editoriale (PDF)
Licenza:
Dominio pubblico
Dimensione
1.08 MB
Formato
Adobe PDF
|
1.08 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.