This study aimed to evaluate intraocular pressure (IOP) estimates in healthy eyes of Caretta caretta using rebound tonometry in comparison with applanation tonometry. Twenty-three healthy C. caretta (housed at the Marine Turtle Research Center) without preexisting ophthalmic disease were enrolled in the study. IOP measurements were obtained by the same ophthalmologist, with the turtle in ventral recumbency between 2:30 p.m. and 4:30 p.m., using a rebound tonometer (RT; TonoVet) in dog calibration mode, and after topical anesthesia, an applanation tonometer (AT; Tono-Pen) in both eyes. The average of three readings per instrument was used for analysis. The agreement between the two tonometers was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC). Moreover, differences in IOP between the two tonometers were analyzed using the Mann-Whitney test. Moderate agreement was found between the two tonometers (ICC, 0.663; 95% confidence interval, 0.206-0.857). The median, Q1, and Q3 IOP obtained with AT (6.2, 4.7, and 9.1 mm Hg) were significantly lower (P¼0.001) than that obtained with RT (9.7, 8.3, and 11.6 mm Hg). It was not possible to obtain an instrument automatically generated mean of four values with AT because of retraction of the globe by the animals, and IOP measurement was unsuccessful in 7 eyes. In conclusion, IOP readings from the RT were statistically higher than those from the AT. RT proved to be more feasible because of the light, short-lasting contact with the cornea.

Comparison of intraocular pressure measurement using rebound and applanation tonometry in loggerhead (Caretta caretta) sea turtles / Lamagna, B.; Affuso, A.; Micieli, F.; Mennonna, G.; Meomartino, L.; della Valle, G.; Ciampa, M.; Treglia, G.; Hochscheid, S.. - In: JOURNAL OF ZOO AND WILDLIFE MEDICINE. - ISSN 1042-7260. - 52:2(2021), pp. 604-609. [10.1638/2020-0070]

Comparison of intraocular pressure measurement using rebound and applanation tonometry in loggerhead (Caretta caretta) sea turtles

Lamagna B.;Micieli F.;Mennonna G.;Meomartino L.;della Valle G.;
2021

Abstract

This study aimed to evaluate intraocular pressure (IOP) estimates in healthy eyes of Caretta caretta using rebound tonometry in comparison with applanation tonometry. Twenty-three healthy C. caretta (housed at the Marine Turtle Research Center) without preexisting ophthalmic disease were enrolled in the study. IOP measurements were obtained by the same ophthalmologist, with the turtle in ventral recumbency between 2:30 p.m. and 4:30 p.m., using a rebound tonometer (RT; TonoVet) in dog calibration mode, and after topical anesthesia, an applanation tonometer (AT; Tono-Pen) in both eyes. The average of three readings per instrument was used for analysis. The agreement between the two tonometers was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC). Moreover, differences in IOP between the two tonometers were analyzed using the Mann-Whitney test. Moderate agreement was found between the two tonometers (ICC, 0.663; 95% confidence interval, 0.206-0.857). The median, Q1, and Q3 IOP obtained with AT (6.2, 4.7, and 9.1 mm Hg) were significantly lower (P¼0.001) than that obtained with RT (9.7, 8.3, and 11.6 mm Hg). It was not possible to obtain an instrument automatically generated mean of four values with AT because of retraction of the globe by the animals, and IOP measurement was unsuccessful in 7 eyes. In conclusion, IOP readings from the RT were statistically higher than those from the AT. RT proved to be more feasible because of the light, short-lasting contact with the cornea.
2021
Comparison of intraocular pressure measurement using rebound and applanation tonometry in loggerhead (Caretta caretta) sea turtles / Lamagna, B.; Affuso, A.; Micieli, F.; Mennonna, G.; Meomartino, L.; della Valle, G.; Ciampa, M.; Treglia, G.; Hochscheid, S.. - In: JOURNAL OF ZOO AND WILDLIFE MEDICINE. - ISSN 1042-7260. - 52:2(2021), pp. 604-609. [10.1638/2020-0070]
File in questo prodotto:
File Dimensione Formato  
2020 IOP caretta Lamagna.pdf

solo utenti autorizzati

Descrizione: Articolo principale
Tipologia: Versione Editoriale (PDF)
Licenza: Accesso privato/ristretto
Dimensione 280.8 kB
Formato Adobe PDF
280.8 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/857773
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact