Objectives: This study sought to evaluate 30-day safety and efficacy of dual-layer mesh-covered carotid stent systems for carotid artery stenting (CAS) in the clinical practice. Background: When compared with carotid endarterectomy, CAS has been associated with a higher rate of post procedural neurologic events; these could be related to plaque's debris prolapsing through stent's mesh. Consequently, the need for increased plaque coverage has resulted in the development of dual-layer mesh-covered carotid stent systems. Methods: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system in 20 centers. The primary endpoint was stroke up to 30 days; secondary endpoints were technical and procedural success; external carotid artery occlusion; and in-hospital and 30-day transient ischemic attack (TIA), acute myocardial infarction (AMI), and death rates. Results: Symptoms were present in 131 (17.87%) patients. An embolic protection device was used in 731 (99.72%) patients. Procedural success was 100%, technical success was obtained in all but 1 (99.86%) patient, who died in hospital due to a hemorrhagic stroke. Six TIAs, 2 minor strokes, and 1 AMI occurred during in-hospital stay, and external carotid artery occlusion was evident in 8 (1.09%) patients. Between hospital discharge and 30-day follow-up, 2 TIAs, 1 minor stroke, and 3 AMIs occurred. Therefore, the cumulative stroke rate was 0.54%. Conclusions: This real-world registry suggests that use of CGuard embolic prevention system in clinical practice is safe and associated with a minimal occurrence of adverse neurological events up to 30-day follow-up.

1-Month Results From a Prospective Experience on CAS Using CGuard Stent System: The IRONGUARD 2 Study / Sirignano, P.; Stabile, E.; Mansour, W.; Capoccia, L.; Faccenna, F.; Intrieri, F.; Ferri, M.; Sacca, S.; Sponza, M.; Mortola, P.; Ronchey, S.; Grillo, P.; Chiappa, R.; Losa, S.; Setacci, F.; Pirrelli, S.; Taurino, M.; Ruffino, M. A.; Udini, M.; Palombo, D.; Ippoliti, A.; Montelione, N.; Setacci, C.; de Donato, G.; Ruggeri, M.; Speziale, F.. - In: JACC: CARDIOVASCULAR INTERVENTIONS. - ISSN 1936-8798. - 13:18(2020), pp. 2170-2177. [10.1016/j.jcin.2020.05.026]

1-Month Results From a Prospective Experience on CAS Using CGuard Stent System: The IRONGUARD 2 Study

Sirignano P.;Stabile E.;de Donato G.;
2020

Abstract

Objectives: This study sought to evaluate 30-day safety and efficacy of dual-layer mesh-covered carotid stent systems for carotid artery stenting (CAS) in the clinical practice. Background: When compared with carotid endarterectomy, CAS has been associated with a higher rate of post procedural neurologic events; these could be related to plaque's debris prolapsing through stent's mesh. Consequently, the need for increased plaque coverage has resulted in the development of dual-layer mesh-covered carotid stent systems. Methods: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system in 20 centers. The primary endpoint was stroke up to 30 days; secondary endpoints were technical and procedural success; external carotid artery occlusion; and in-hospital and 30-day transient ischemic attack (TIA), acute myocardial infarction (AMI), and death rates. Results: Symptoms were present in 131 (17.87%) patients. An embolic protection device was used in 731 (99.72%) patients. Procedural success was 100%, technical success was obtained in all but 1 (99.86%) patient, who died in hospital due to a hemorrhagic stroke. Six TIAs, 2 minor strokes, and 1 AMI occurred during in-hospital stay, and external carotid artery occlusion was evident in 8 (1.09%) patients. Between hospital discharge and 30-day follow-up, 2 TIAs, 1 minor stroke, and 3 AMIs occurred. Therefore, the cumulative stroke rate was 0.54%. Conclusions: This real-world registry suggests that use of CGuard embolic prevention system in clinical practice is safe and associated with a minimal occurrence of adverse neurological events up to 30-day follow-up.
2020
1-Month Results From a Prospective Experience on CAS Using CGuard Stent System: The IRONGUARD 2 Study / Sirignano, P.; Stabile, E.; Mansour, W.; Capoccia, L.; Faccenna, F.; Intrieri, F.; Ferri, M.; Sacca, S.; Sponza, M.; Mortola, P.; Ronchey, S.; Grillo, P.; Chiappa, R.; Losa, S.; Setacci, F.; Pirrelli, S.; Taurino, M.; Ruffino, M. A.; Udini, M.; Palombo, D.; Ippoliti, A.; Montelione, N.; Setacci, C.; de Donato, G.; Ruggeri, M.; Speziale, F.. - In: JACC: CARDIOVASCULAR INTERVENTIONS. - ISSN 1936-8798. - 13:18(2020), pp. 2170-2177. [10.1016/j.jcin.2020.05.026]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/842688
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 12
social impact