We present the implementation of the CT iterative reconstruction strategy developed within the SYRMA-CT project for in vivo phase contrast CT of the uncompressed breast, ongoing at the ELETTRA synchrotron radiation facility (Trieste, Italy). Propagation-based phase-contrast imaging exploited the high spatial coherence of the monoenergetic laminar X-ray beam (3-mm high along the chest-wall-to-nipple direction), as well as the large object-to-detector distance (~2 m) and the use of a prototype of Pixirad-8 high-resolution photon counting CdTe detector (60-μm pitch, eight detector units arranged in a row). The signal in projection views depends on the X-ray absorption as well as on the phase shift introduced by the breast tissue in the beam path. A phase retrieval algorithm allows recovering the projected 2D phase map of the irradiated tissue layer, which were input to the CT reconstruction; then, the 3D image of the breast was reconstructed via a simultaneous algebraic reconstruction technique (SART) algorithm. The developed iterative reconstruction - coupled with a filtering process for reducing the noise level and ring artifacts by preserving edges sharpness - showed better image quality than conventional filtered backprojection (FBP) reconstruction. A phantom study showed that the iterative reconstruction produced images with a contrast-to-noise-ratio up to 65% and a spatial resolution up to 12% higher than those obtained with FBP. Finally, the developed algorithm removed ring-like artifacts caused by the detector dead space (0.16 mm) across adjacent detector units and by no perfect equalization after flat-field correction, without worsening the image quality.

A framework for iterative reconstruction in phase-contrast computed tomography dedicated to the breast / Sarno, A.; Golosio, B.; Russo, P.; Arfelli, F.; Bellazzini, R.; Brez, A.; Brun, F.; Delogu, P.; Di Lillo, F.; Dreossi, D.; Fedon, C.; Longo, R.; Mettivier, G.; Oliva, P.; Rigon, L.; Spandre, G.; Tromba, G.. - (2016), pp. 1-3. (Intervento presentato al convegno 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), Strasbourg, 2016 tenutosi a Strasbourg, France nel 29 Ottobre - 6 Novembre 2016) [10.1109/NSSMIC.2016.8069483].

A framework for iterative reconstruction in phase-contrast computed tomography dedicated to the breast

Sarno, A.;Russo, P.;Di Lillo, F.;Mettivier, G.;
2016

Abstract

We present the implementation of the CT iterative reconstruction strategy developed within the SYRMA-CT project for in vivo phase contrast CT of the uncompressed breast, ongoing at the ELETTRA synchrotron radiation facility (Trieste, Italy). Propagation-based phase-contrast imaging exploited the high spatial coherence of the monoenergetic laminar X-ray beam (3-mm high along the chest-wall-to-nipple direction), as well as the large object-to-detector distance (~2 m) and the use of a prototype of Pixirad-8 high-resolution photon counting CdTe detector (60-μm pitch, eight detector units arranged in a row). The signal in projection views depends on the X-ray absorption as well as on the phase shift introduced by the breast tissue in the beam path. A phase retrieval algorithm allows recovering the projected 2D phase map of the irradiated tissue layer, which were input to the CT reconstruction; then, the 3D image of the breast was reconstructed via a simultaneous algebraic reconstruction technique (SART) algorithm. The developed iterative reconstruction - coupled with a filtering process for reducing the noise level and ring artifacts by preserving edges sharpness - showed better image quality than conventional filtered backprojection (FBP) reconstruction. A phantom study showed that the iterative reconstruction produced images with a contrast-to-noise-ratio up to 65% and a spatial resolution up to 12% higher than those obtained with FBP. Finally, the developed algorithm removed ring-like artifacts caused by the detector dead space (0.16 mm) across adjacent detector units and by no perfect equalization after flat-field correction, without worsening the image quality.
2016
978-1-5090-1642-6
A framework for iterative reconstruction in phase-contrast computed tomography dedicated to the breast / Sarno, A.; Golosio, B.; Russo, P.; Arfelli, F.; Bellazzini, R.; Brez, A.; Brun, F.; Delogu, P.; Di Lillo, F.; Dreossi, D.; Fedon, C.; Longo, R.; Mettivier, G.; Oliva, P.; Rigon, L.; Spandre, G.; Tromba, G.. - (2016), pp. 1-3. (Intervento presentato al convegno 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), Strasbourg, 2016 tenutosi a Strasbourg, France nel 29 Ottobre - 6 Novembre 2016) [10.1109/NSSMIC.2016.8069483].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/837584
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 0
social impact