Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of (22±3) tonne day. Above ∼0.4 keVee, we observe <1 event/(tonne day keVee), which is more than 1000 times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses mχ within 3-6 GeV/c2, DM-electron scattering for mχ>30 MeV/c2, and absorption of dark photons and axionlike particles for mχ within 0.186-1 keV/c2.
Light Dark Matter Search with Ionization Signals in XENON1T / Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Antochi, V. C.; Angelino, E.; Arneodo, F.; Barge, D.; Baudis, L.; Bauermeister, B.; Bellagamba, L.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; De Perio, P.; Depoian, A.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Elykov, A.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Gaemers, P.; Gallo Rosso, A.; Galloway, M.; Gao, F.; Garbini, M.; Grandi, L.; Greene, Z.; Hasterok, C.; Hils, C.; Hogenbirk, E.; Howlett, J.; Iacovacci, M.; Itay, R.; Joerg, F.; Kazama, S.; Kish, A.; Kobayashi, M.; Koltman, G.; Kopec, A.; Landsman, H.; Lang, R. F.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Lopez Fune, E.; Macolino, C.; Mahlstedt, J.; Manfredini, A.; Marignetti, F.; Marrodan Undagoitia, T.; Masbou, J.; Mastroianni, S.; Messina, M.; Micheneau, K.; Miller, K.; Molinario, A.; Mora, K.; Mosbacher, Y.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Odgers, K.; Palacio, J.; Pelssers, B.; Peres, R.; Pienaar, J.; Pizzella, V.; Plante, G.; Podviianiuk, R.; Qin, J.; Qiu, H.; Ramirez Garcia, D.; Reichard, S.; Riedel, B.; Rocchetti, A.; Rupp, N.; Dos Santos, J. M. F.; Sartorelli, G.; Sarcevic, N.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schulte, D.; Schumann, M.; Scotto Lavina, L.; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Therreau, C.; Thers, D.; Toschi, F.; Trinchero, G.; Tunnell, C.; Upole, N.; Vargas, M.; Volta, G.; Wack, O.; Wang, H.; Wei, Y.; Weinheimer, C.; Wenz, D.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.; Zhu, T.; Zopounidis, J. P.. - In: PHYSICAL REVIEW LETTERS. - ISSN 0031-9007. - 123:25(2019), p. 251801. [10.1103/PhysRevLett.123.251801]
Light Dark Matter Search with Ionization Signals in XENON1T
Aprile E.;Aalbers J.;Agostini F.;Alfonsi M.;Althueser L.;Amaro F. D.;Antochi V. C.;Angelino E.;Arneodo F.;Barge D.;Baudis L.;Bauermeister B.;Bellagamba L.;Benabderrahmane M. L.;Berger T.;Breur P. A.;Brown A.;Brown E.;Bruenner S.;Bruno G.;Budnik R.;Capelli C.;Cardoso J. M. R.;Cichon D.;Coderre D.;Colijn A. P.;Conrad J.;Cussonneau J. P.;Decowski M. P.;De Perio P.;Depoian A.;Di Gangi P.;Di Giovanni A.;Diglio S.;Elykov A.;Eurin G.;Fei J.;Ferella A. D.;Fieguth A.;Fulgione W.;Gaemers P.;Gallo Rosso A.;Galloway M.;Gao F.;Garbini M.;Grandi L.;Greene Z.;Hasterok C.;Hils C.;Hogenbirk E.;Howlett J.;Iacovacci M.;Itay R.;Joerg F.;Kazama S.;Kish A.;Kobayashi M.;Koltman G.;Kopec A.;Landsman H.;Lang R. F.;Levinson L.;Lin Q.;Lindemann S.;Lindner M.;Lombardi F.;Lopes J. A. M.;Lopez Fune E.;Macolino C.;Mahlstedt J.;Manfredini A.;Marignetti F.;Marrodan Undagoitia T.;Masbou J.;Mastroianni S.;Messina M.;Micheneau K.;Miller K.;Molinario A.;Mora K.;Mosbacher Y.;Murra M.;Naganoma J.;Ni K.;Oberlack U.;Odgers K.;Palacio J.;Pelssers B.;Peres R.;Pienaar J.;Pizzella V.;Plante G.;Podviianiuk R.;Qin J.;Qiu H.;Ramirez Garcia D.;Reichard S.;Riedel B.;Rocchetti A.;Rupp N.;Dos Santos J. M. F.;Sartorelli G.;Sarcevic N.;Scheibelhut M.;Schindler S.;Schreiner J.;Schulte D.;Schumann M.;Scotto Lavina L.;Selvi M.;Shagin P.;Shockley E.;Silva M.;Simgen H.;Therreau C.;Thers D.;Toschi F.;Trinchero G.;Tunnell C.;Upole N.;Vargas M.;Volta G.;Wack O.;Wang H.;Wei Y.;Weinheimer C.;Wenz D.;Wittweg C.;Wulf J.;Ye J.;Zhang Y.;Zhu T.;Zopounidis J. P.
2019
Abstract
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of (22±3) tonne day. Above ∼0.4 keVee, we observe <1 event/(tonne day keVee), which is more than 1000 times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses mχ within 3-6 GeV/c2, DM-electron scattering for mχ>30 MeV/c2, and absorption of dark photons and axionlike particles for mχ within 0.186-1 keV/c2.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/836528
Citazioni
ND
414
380
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.