In high-brightness electron linear accelerators (LINACs), the particle bunch length is measured by a radio frequency deflector (RFD). The electron bunch is deflected vertically toward a screen and its length can be obtained using vertical spot size measurements after a proper calibration, e.g., measuring the vertical bunch centroid while varying the deflecting voltage phase. The energy parameters of the bunch (the energy chirp and the energy spread) and the correlation between particle positions, divergences, and energies contribute to the bunch vertical dimension at the screen position after the RFD and so far were considered as a source of systematic errors in a bunch length measurement. The measurement theory and production model for bunch length, energy spread and chirp, as well as correlations are described. As usual in particle accelerators physics, the method is validated using numerical simulations of state-of-the-art LINACs with a reference simulation code showing a typical accuracy in the few percent levels.

A Measurement Method Based on RF Deflector for Particle Bunch Longitudinal Parameters in Linear Accelerators / Sabato, L.; Arpaia, P.; Gilardi, A.; Mostacci, A.; Palumbo, L.; Variola, A.. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - 70:(2021), pp. 1-9. [10.1109/TIM.2020.3009342]

A Measurement Method Based on RF Deflector for Particle Bunch Longitudinal Parameters in Linear Accelerators

Arpaia P.;Gilardi A.;
2021

Abstract

In high-brightness electron linear accelerators (LINACs), the particle bunch length is measured by a radio frequency deflector (RFD). The electron bunch is deflected vertically toward a screen and its length can be obtained using vertical spot size measurements after a proper calibration, e.g., measuring the vertical bunch centroid while varying the deflecting voltage phase. The energy parameters of the bunch (the energy chirp and the energy spread) and the correlation between particle positions, divergences, and energies contribute to the bunch vertical dimension at the screen position after the RFD and so far were considered as a source of systematic errors in a bunch length measurement. The measurement theory and production model for bunch length, energy spread and chirp, as well as correlations are described. As usual in particle accelerators physics, the method is validated using numerical simulations of state-of-the-art LINACs with a reference simulation code showing a typical accuracy in the few percent levels.
2021
A Measurement Method Based on RF Deflector for Particle Bunch Longitudinal Parameters in Linear Accelerators / Sabato, L.; Arpaia, P.; Gilardi, A.; Mostacci, A.; Palumbo, L.; Variola, A.. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - 70:(2021), pp. 1-9. [10.1109/TIM.2020.3009342]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/831793
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 2
social impact