This article deals with the parameters’ measurement of interarea oscillations, which are low-frequency damped oscillations that affect the high-voltage transmission lines when an unbalance between the power demand and the generated power occurs. The authors propose a method that processes the samples provided by the phasor measurement unit (PMU) and performs the online estimation of the parameters that characterize the interarea oscillations. The method takes advantage of the speed of a heuristic algorithm, such as the particle swarm optimization (PSO), but performs an enhancement on the results to increase the reliability. The tests carried out for the method assessment prove that the proposed method is characterized by a fast response, high accuracy, and excellent reliability, regardless of the type of oscillation that is considered.

A PSO-MMA Method for the Parameters Estimation of Interarea Oscillations in Electrical Grids / Bonavolonta, Francesco; Di Noia, Luigi Pio; Liccardo, Annalisa; Tessitore, Salvatore; Lauria, Davide. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - 69:11(2020), pp. 8853-8865. [10.1109/TIM.2020.2998909]

A PSO-MMA Method for the Parameters Estimation of Interarea Oscillations in Electrical Grids

Bonavolonta, Francesco;Di Noia, Luigi Pio;Liccardo, Annalisa
;
Tessitore, Salvatore;Lauria, Davide
2020

Abstract

This article deals with the parameters’ measurement of interarea oscillations, which are low-frequency damped oscillations that affect the high-voltage transmission lines when an unbalance between the power demand and the generated power occurs. The authors propose a method that processes the samples provided by the phasor measurement unit (PMU) and performs the online estimation of the parameters that characterize the interarea oscillations. The method takes advantage of the speed of a heuristic algorithm, such as the particle swarm optimization (PSO), but performs an enhancement on the results to increase the reliability. The tests carried out for the method assessment prove that the proposed method is characterized by a fast response, high accuracy, and excellent reliability, regardless of the type of oscillation that is considered.
2020
A PSO-MMA Method for the Parameters Estimation of Interarea Oscillations in Electrical Grids / Bonavolonta, Francesco; Di Noia, Luigi Pio; Liccardo, Annalisa; Tessitore, Salvatore; Lauria, Davide. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - 69:11(2020), pp. 8853-8865. [10.1109/TIM.2020.2998909]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/819288
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 12
social impact