Time domain reflectometry (TDR) is a robust approach for measuring static electrical conductivity of moistened granular materials. Although initially introduced for monitoring soil salinity, its application to granular materials might be an interesting and cost-effective means for monitoring the quality-status of various materials. However, the traditional approach requires tedious and time-consuming preliminary calibration measurements on reference liquids. In this paper, an innovative approach for the direct estimation of the electrical conductivity is presented. In fact, it is demonstrated that the suitable combination of the TDR measurement with a transmission-line modeling of the measurement setup, successfully leads to the avoidance of the preliminary calibration procedure. Investigations carried out on water and on moistened sand samples demonstrate that the performance of the proposed method in estimating the static conductivity is comparable with that achievable through the traditional approach. © 2009 IEEE.

An innovative method for TDR measurement of static electrical conductivity in granular materials / Cannazza, G.; Cataldo, A.; De Benedetto, E.; Piuzzi, E.. - (2009), pp. 197-200. (Intervento presentato al convegno 2009 IEEE Instrumentation and Measurement Technology Conference tenutosi a Singapore nel 5-7 May 2009) [10.1109/IMTC.2009.5168442].

An innovative method for TDR measurement of static electrical conductivity in granular materials

De Benedetto E.;
2009

Abstract

Time domain reflectometry (TDR) is a robust approach for measuring static electrical conductivity of moistened granular materials. Although initially introduced for monitoring soil salinity, its application to granular materials might be an interesting and cost-effective means for monitoring the quality-status of various materials. However, the traditional approach requires tedious and time-consuming preliminary calibration measurements on reference liquids. In this paper, an innovative approach for the direct estimation of the electrical conductivity is presented. In fact, it is demonstrated that the suitable combination of the TDR measurement with a transmission-line modeling of the measurement setup, successfully leads to the avoidance of the preliminary calibration procedure. Investigations carried out on water and on moistened sand samples demonstrate that the performance of the proposed method in estimating the static conductivity is comparable with that achievable through the traditional approach. © 2009 IEEE.
2009
978-1-4244-3352-0
An innovative method for TDR measurement of static electrical conductivity in granular materials / Cannazza, G.; Cataldo, A.; De Benedetto, E.; Piuzzi, E.. - (2009), pp. 197-200. (Intervento presentato al convegno 2009 IEEE Instrumentation and Measurement Technology Conference tenutosi a Singapore nel 5-7 May 2009) [10.1109/IMTC.2009.5168442].
File in questo prodotto:
File Dimensione Formato  
An innovative method for TDR measurement of static electrical conductivity in granular materials.pdf

non disponibili

Descrizione: An Innovative Method for TDR Measurement of Static Electrical Conductivity in Granular Materials
Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 461.67 kB
Formato Adobe PDF
461.67 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/807211
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact