In this paper, two customized systems for microwave permittivity measurements on liquid samples, based on reflectometric measurements, are presented and analyzed. Their performance is compared against the one deriving from the widely adopted commercial measurement setup, based on an open-ended coaxial line. The first custom system is built by properly modifying an N-type coaxial connector and relies on vector reflection coefficient measurements, while the second one uses a portion of liquid-filled coaxial line in conjunction with a time-domain reflectometry equipment. The systems are built for quality control and diagnostic purposes and their final aim is to extract the Cole & Cole dielectric model of the liquid under test. In order to metrologically characterize the systems, a series of repeated measurements is performed on a set of reference liquids. After the Cole & Cole parameters are extracted for each considered measurement method, the resulting type A uncertainty is evaluated. Comparison with literature reference data for the liquids also allows estimation of measurement bias. The analysis evidences that custom probes generally exhibit an acceptable measurement bias, but with a relevant loss of accuracy in the estimation of some Cole & Cole parameters for lossy liquids. Possible improvements are under investigation for enhancing their performance and make them appealing substitutes for the commercial setup. © 2012 IEEE.

Customized systems for complex permittivity measurements on liquid samples at microwave frequencies: A comparative analysis / Apollonio, F.; Liberti, M.; Piuzzi, E.; Cannazza, G.; Cataldo, A.; De Benedetto, E.; D'Atanasio, P.; Merla, C.; Zambotti, A.. - (2012), pp. 1617-1620. (Intervento presentato al convegno 2012 IEEE I2MTC - International Instrumentation and Measurement Technology Conference tenutosi a Graz, Austria nel 13-16 maggio 2012) [10.1109/I2MTC.2012.6229138].

Customized systems for complex permittivity measurements on liquid samples at microwave frequencies: A comparative analysis

De Benedetto E.;
2012

Abstract

In this paper, two customized systems for microwave permittivity measurements on liquid samples, based on reflectometric measurements, are presented and analyzed. Their performance is compared against the one deriving from the widely adopted commercial measurement setup, based on an open-ended coaxial line. The first custom system is built by properly modifying an N-type coaxial connector and relies on vector reflection coefficient measurements, while the second one uses a portion of liquid-filled coaxial line in conjunction with a time-domain reflectometry equipment. The systems are built for quality control and diagnostic purposes and their final aim is to extract the Cole & Cole dielectric model of the liquid under test. In order to metrologically characterize the systems, a series of repeated measurements is performed on a set of reference liquids. After the Cole & Cole parameters are extracted for each considered measurement method, the resulting type A uncertainty is evaluated. Comparison with literature reference data for the liquids also allows estimation of measurement bias. The analysis evidences that custom probes generally exhibit an acceptable measurement bias, but with a relevant loss of accuracy in the estimation of some Cole & Cole parameters for lossy liquids. Possible improvements are under investigation for enhancing their performance and make them appealing substitutes for the commercial setup. © 2012 IEEE.
2012
978-1-4577-1772-7
978-1-4577-1773-4
978-1-4577-1771-0
Customized systems for complex permittivity measurements on liquid samples at microwave frequencies: A comparative analysis / Apollonio, F.; Liberti, M.; Piuzzi, E.; Cannazza, G.; Cataldo, A.; De Benedetto, E.; D'Atanasio, P.; Merla, C.; Zambotti, A.. - (2012), pp. 1617-1620. (Intervento presentato al convegno 2012 IEEE I2MTC - International Instrumentation and Measurement Technology Conference tenutosi a Graz, Austria nel 13-16 maggio 2012) [10.1109/I2MTC.2012.6229138].
File in questo prodotto:
File Dimensione Formato  
Customized systems for complex permittivity.pdf

non disponibili

Descrizione: Customized Systems for Complex Permittivity Measurements on Liquid Samples at Microwave Frequencies: a Comparative Analysis
Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 313.14 kB
Formato Adobe PDF
313.14 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/807204
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact