In previous works, the authors have explored the use of a microwave reflectometry-based system for the automatic control and real-time monitoring of the flow and of the liquid level in intravenous medical infusions. In this paper, the repeatability of the measurements obtained with the proposed method is evaluated, by employing an ad-hoc experimental procedure. Preliminary results demonstrate that the method shows a good repeatability; nevertheless, there are still some issues that should be solved. © 2012 IEEE.

Reproducibility analysis of a TDR-based monitoring system for intravenous drip infusions: Validation of a novel method for flow-rate measurement in IV infusion / Cataldo, Andrea; Cannazza, Giuseppe; DE BENEDETTO, Egidio; Giaquinto, Nicola; Trotta, Amerigo. - (2012), pp. 203-207. (Intervento presentato al convegno 2012 IEEE Symposium on Medical Measurements and Applications, MeMeA 2012 tenutosi a Budapest, hungary nel 2012) [10.1109/MeMeA.2012.6226673].

Reproducibility analysis of a TDR-based monitoring system for intravenous drip infusions: Validation of a novel method for flow-rate measurement in IV infusion

Egidio De Benedetto;
2012

Abstract

In previous works, the authors have explored the use of a microwave reflectometry-based system for the automatic control and real-time monitoring of the flow and of the liquid level in intravenous medical infusions. In this paper, the repeatability of the measurements obtained with the proposed method is evaluated, by employing an ad-hoc experimental procedure. Preliminary results demonstrate that the method shows a good repeatability; nevertheless, there are still some issues that should be solved. © 2012 IEEE.
2012
978-1-4673-0882-3
978-1-4673-0880-9
978-1-4673-0881-6
Reproducibility analysis of a TDR-based monitoring system for intravenous drip infusions: Validation of a novel method for flow-rate measurement in IV infusion / Cataldo, Andrea; Cannazza, Giuseppe; DE BENEDETTO, Egidio; Giaquinto, Nicola; Trotta, Amerigo. - (2012), pp. 203-207. (Intervento presentato al convegno 2012 IEEE Symposium on Medical Measurements and Applications, MeMeA 2012 tenutosi a Budapest, hungary nel 2012) [10.1109/MeMeA.2012.6226673].
File in questo prodotto:
File Dimensione Formato  
Reproducibility analysis of a TDR-based monitoring system.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 1.02 MB
Formato Adobe PDF
1.02 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/807203
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? ND
social impact