A time domain reflectometry (TDR)-based system for the localization of water leaks has been recently developed by the authors. This system, which employs wire-like sensing elements to be installed along the underground pipes, has proven immune to the limitations that affect the traditional, acoustic leak-detection systems. Starting from the positive results obtained thus far, in this work, an improvement of this TDR-based system is proposed. More specifically, the possibility of employing a low-cost, water-absorbing sponge to be placed around the sensing element for enhancing the accuracy in the localization of the leak is addressed. To this purpose, laboratory experiments were carried out mimicking a water leakage condition, and two sensing elements (one embedded in a sponge and one without sponge) were comparatively used to identify the position of the leak through TDR measurements. Results showed that, thanks to the water retention capability of the sponge (which maintains the leaked water more localized), the sensing element embedded in the sponge leads to a higher accuracy in the evaluation of the position of the leak.

Accuracy improvement in the TDR-based localization of water leaks / Cataldo, A.; De Benedetto, E.; Cannazza, G.; Monti, G.; Demitri, C.. - In: RESULTS IN PHYSICS. - ISSN 2211-3797. - 6:(2016), pp. 594-598. [10.1016/j.rinp.2016.08.012]

Accuracy improvement in the TDR-based localization of water leaks

De Benedetto E.;
2016

Abstract

A time domain reflectometry (TDR)-based system for the localization of water leaks has been recently developed by the authors. This system, which employs wire-like sensing elements to be installed along the underground pipes, has proven immune to the limitations that affect the traditional, acoustic leak-detection systems. Starting from the positive results obtained thus far, in this work, an improvement of this TDR-based system is proposed. More specifically, the possibility of employing a low-cost, water-absorbing sponge to be placed around the sensing element for enhancing the accuracy in the localization of the leak is addressed. To this purpose, laboratory experiments were carried out mimicking a water leakage condition, and two sensing elements (one embedded in a sponge and one without sponge) were comparatively used to identify the position of the leak through TDR measurements. Results showed that, thanks to the water retention capability of the sponge (which maintains the leaked water more localized), the sensing element embedded in the sponge leads to a higher accuracy in the evaluation of the position of the leak.
2016
Accuracy improvement in the TDR-based localization of water leaks / Cataldo, A.; De Benedetto, E.; Cannazza, G.; Monti, G.; Demitri, C.. - In: RESULTS IN PHYSICS. - ISSN 2211-3797. - 6:(2016), pp. 594-598. [10.1016/j.rinp.2016.08.012]
File in questo prodotto:
File Dimensione Formato  
Results_in_physics_paper_Leak_detection.pdf

accesso aperto

Descrizione: Versione pubblicata Accuracy improvement in the TDR-based localization of water leaks
Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 1.34 MB
Formato Adobe PDF
1.34 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/806777
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 8
social impact