BACKGROUND: We measured myocardial blood flow (MBF) and perfusion reserve (MPR) by dynamic CZT-SPECT and 82Rb-PET in patients with suspected or known coronary artery disease (CAD) and compared the accuracy of the two methods in predicting obstructive CAD. METHODS: Twenty-five patients with available coronary angiography data underwent 99mTc-sestamibi CZT-SPECT and 82Rb-PET cardiac imaging. Stress and rest MBF and MPR were calculated by both methods and compared. Diagnostic accuracies of CZT-SPECT and PET were also assessed using a receiver-operator-characteristic curve. RESULTS: CZT-SPECT yielded similar baseline MBF, but higher hyperemic MBF and MPR values compared to PET. There was a modest correlation between the two methods for MPR (r = 0.56, P < .01). MPR by CZT-SPECT showed a good ability in identify a reduced MPR by PET, with an area under the curve of 0.85. A MPR cut-off of 2.5 was identified by CZT-SPECT for detection of abnormal MPR by PET, with a sensitivity, specificity and accuracy of 86%, 73% and 80%. The area under the curve for the identification of obstructive CAD by regional MPR were 0.83 for CZT-SPECT and 0.84 for PET (P = .90). At CZT-SPECT, a regional MPR of 2.1 provided the best trade-off between sensitivity and specificity for identifying obstructive CAD. Diagnostic accuracy of CZT-SPECT and PET using respective cut-off values was comparable (P = .62). CONCLUSION: Hyperemic MBF and MPR values obtained by CZT-SPECT are higher than those measured by 82Rb-PET imaging, with a moderate correlation between the two methods. CZT-SPECT shows good diagnostic accuracy for the identification of obstructive CAD. These findings may encourage the use of this new technique to a better risk stratification and patient management.

Quantification of myocardial perfusion reserve by CZT-SPECT: A head to head comparison with 82Rubidium PET imaging / Acampa, Wanda; Zampella, Emilia; Assante, Roberta; Genova, Andrea; De Simini, Giovanni; Mannarino, Teresa; D'Antonio, Adriana; Gaudieri, Valeria; Nappi, Carmela; Buongiorno, Pietro; Mainolfi, Ciro Gabriele; Petretta, Mario; Cuocolo, Alberto. - In: JOURNAL OF NUCLEAR CARDIOLOGY. - ISSN 1071-3581. - 28:6(2021), pp. 2827-2839. [10.1007/s12350-020-02129-w]

Quantification of myocardial perfusion reserve by CZT-SPECT: A head to head comparison with 82Rubidium PET imaging

Acampa, Wanda;Zampella, Emilia;Assante, Roberta;Genova, Andrea;De Simini, Giovanni;Mannarino, Teresa;D'Antonio, Adriana;Gaudieri, Valeria;Nappi, Carmela;Buongiorno, Pietro;Mainolfi, Ciro Gabriele
;
Petretta, Mario;Cuocolo, Alberto
2021

Abstract

BACKGROUND: We measured myocardial blood flow (MBF) and perfusion reserve (MPR) by dynamic CZT-SPECT and 82Rb-PET in patients with suspected or known coronary artery disease (CAD) and compared the accuracy of the two methods in predicting obstructive CAD. METHODS: Twenty-five patients with available coronary angiography data underwent 99mTc-sestamibi CZT-SPECT and 82Rb-PET cardiac imaging. Stress and rest MBF and MPR were calculated by both methods and compared. Diagnostic accuracies of CZT-SPECT and PET were also assessed using a receiver-operator-characteristic curve. RESULTS: CZT-SPECT yielded similar baseline MBF, but higher hyperemic MBF and MPR values compared to PET. There was a modest correlation between the two methods for MPR (r = 0.56, P < .01). MPR by CZT-SPECT showed a good ability in identify a reduced MPR by PET, with an area under the curve of 0.85. A MPR cut-off of 2.5 was identified by CZT-SPECT for detection of abnormal MPR by PET, with a sensitivity, specificity and accuracy of 86%, 73% and 80%. The area under the curve for the identification of obstructive CAD by regional MPR were 0.83 for CZT-SPECT and 0.84 for PET (P = .90). At CZT-SPECT, a regional MPR of 2.1 provided the best trade-off between sensitivity and specificity for identifying obstructive CAD. Diagnostic accuracy of CZT-SPECT and PET using respective cut-off values was comparable (P = .62). CONCLUSION: Hyperemic MBF and MPR values obtained by CZT-SPECT are higher than those measured by 82Rb-PET imaging, with a moderate correlation between the two methods. CZT-SPECT shows good diagnostic accuracy for the identification of obstructive CAD. These findings may encourage the use of this new technique to a better risk stratification and patient management.
2021
Quantification of myocardial perfusion reserve by CZT-SPECT: A head to head comparison with 82Rubidium PET imaging / Acampa, Wanda; Zampella, Emilia; Assante, Roberta; Genova, Andrea; De Simini, Giovanni; Mannarino, Teresa; D'Antonio, Adriana; Gaudieri, Valeria; Nappi, Carmela; Buongiorno, Pietro; Mainolfi, Ciro Gabriele; Petretta, Mario; Cuocolo, Alberto. - In: JOURNAL OF NUCLEAR CARDIOLOGY. - ISSN 1071-3581. - 28:6(2021), pp. 2827-2839. [10.1007/s12350-020-02129-w]
File in questo prodotto:
File Dimensione Formato  
Acampa et al. J Nucl Cardiol (2021).pdf

solo utenti autorizzati

Descrizione: Articolo su rivista
Tipologia: Versione Editoriale (PDF)
Licenza: Accesso privato/ristretto
Dimensione 1.24 MB
Formato Adobe PDF
1.24 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/805797
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 45
social impact