Surgical access complications during endovascular aneurysm repair (EVAR) are reported relatively frequent. HARMONIC FOCUS® (HF; Ethicon Endo-Surgery Inc., Cincinnati, Ohio, USA) is a device developed to improve bleeding control and reduce heat-related damage stemming from surgical preparation. The aim of this study was to evaluate outcomes and safety of HF versus conventional haemostasis with electrocautery, both techniques used in the same patient. Five patients developed bilateral wound's thickening (13.9%) demonstrated at the CT scan, two of whom had no clinical manifestation while in three cases the thickening was associated with lymphocele (4.54%), 2 of which were in the side where the EC was used (5.5%), and 1 case (2.7%), in the HF applied side. One isolated lymphocele occurred at the left groin (2.7%) (tables n.2-3). A Fisher's exact test was conducted between EC and HF on the occurrence of wound healing complications (3/36 for EC and 1/36 for HF) that resulted statistically significant at p<0.05. Focus Harmonic Scalpel has certain advantages than conventional haemostasis in avoiding surgical access complications.

Harmonic Focus Versus Conventional Electrocautery for Femoral Artery Exposure: a "Direct" Comparison on the Same Patients / Maisto, M; Ferrante, L; Giribono, A M; Sodo, M; Panagrosso, M; Peluso, A; Del Guercio, L; Bracale, U M. - In: TRANSLATIONAL MEDICINE @ UNISA. - ISSN 2239-9747. - 21:(2020), pp. 27-30.

Harmonic Focus Versus Conventional Electrocautery for Femoral Artery Exposure: a "Direct" Comparison on the Same Patients

Maisto, M;Giribono, A M;Sodo, M;Panagrosso, M;Peluso, A;Del Guercio, L;Bracale, U M
2020

Abstract

Surgical access complications during endovascular aneurysm repair (EVAR) are reported relatively frequent. HARMONIC FOCUS® (HF; Ethicon Endo-Surgery Inc., Cincinnati, Ohio, USA) is a device developed to improve bleeding control and reduce heat-related damage stemming from surgical preparation. The aim of this study was to evaluate outcomes and safety of HF versus conventional haemostasis with electrocautery, both techniques used in the same patient. Five patients developed bilateral wound's thickening (13.9%) demonstrated at the CT scan, two of whom had no clinical manifestation while in three cases the thickening was associated with lymphocele (4.54%), 2 of which were in the side where the EC was used (5.5%), and 1 case (2.7%), in the HF applied side. One isolated lymphocele occurred at the left groin (2.7%) (tables n.2-3). A Fisher's exact test was conducted between EC and HF on the occurrence of wound healing complications (3/36 for EC and 1/36 for HF) that resulted statistically significant at p<0.05. Focus Harmonic Scalpel has certain advantages than conventional haemostasis in avoiding surgical access complications.
2020
Harmonic Focus Versus Conventional Electrocautery for Femoral Artery Exposure: a "Direct" Comparison on the Same Patients / Maisto, M; Ferrante, L; Giribono, A M; Sodo, M; Panagrosso, M; Peluso, A; Del Guercio, L; Bracale, U M. - In: TRANSLATIONAL MEDICINE @ UNISA. - ISSN 2239-9747. - 21:(2020), pp. 27-30.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/794625
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 1
social impact