Despite the growing use of different wearable inertial systems, increasingly diffused in clinical practice, there is still a lack of knowledge about the agreement between systems based also on different sensor configuration. Aim of the study has been the investigation of the agreement between Opal and G-Walk wearable inertial systems in gait analysis on normal and post stroke subjects. Although both systems are able to describe significant gait differences in the two populations, study results suggest that gait analysis evaluations carried out by different inertial systems does not give completely overlapping estimation about the different parameters and that this must be taken in correct account especially comparing results of clinical trials obtained by different systems and sensor's placements.

Agreement between Opal and G-Walk Wearable Inertial Systems in Gait Analysis on Normal and Pathological Subjects / D'Addio, G.; Donisi, L.; Pagano, G.; Improta, G.; Biancardi, A.; Cesarelli, M.. - 2019:(2019), pp. 3286-3289. (Intervento presentato al convegno 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2019 tenutosi a deu nel 2019) [10.1109/EMBC.2019.8857841].

Agreement between Opal and G-Walk Wearable Inertial Systems in Gait Analysis on Normal and Pathological Subjects

D'Addio G.;Improta G.;Cesarelli M.
2019

Abstract

Despite the growing use of different wearable inertial systems, increasingly diffused in clinical practice, there is still a lack of knowledge about the agreement between systems based also on different sensor configuration. Aim of the study has been the investigation of the agreement between Opal and G-Walk wearable inertial systems in gait analysis on normal and post stroke subjects. Although both systems are able to describe significant gait differences in the two populations, study results suggest that gait analysis evaluations carried out by different inertial systems does not give completely overlapping estimation about the different parameters and that this must be taken in correct account especially comparing results of clinical trials obtained by different systems and sensor's placements.
2019
978-1-5386-1311-5
Agreement between Opal and G-Walk Wearable Inertial Systems in Gait Analysis on Normal and Pathological Subjects / D'Addio, G.; Donisi, L.; Pagano, G.; Improta, G.; Biancardi, A.; Cesarelli, M.. - 2019:(2019), pp. 3286-3289. (Intervento presentato al convegno 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2019 tenutosi a deu nel 2019) [10.1109/EMBC.2019.8857841].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/793440
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 28
social impact