In the framework of the LIQUEFACT project a series of centrifuge tests were conducted at ISMGEO (Italy) to verify the effectiveness of three mitigation techniques against soil liquefaction. This paper is focused on the study of horizontal drains as mitigation measure against liquefaction. The centrifuge layout with horizontal drains was numerically modelled and the change of boundary conditions reproduced by the FE code Plaxis 2D. Additionally, slightly different layouts from those tested in the centrifuge were also modelled to expand the scope of the experimental work. Horizontal drains were installed in the model, to analyse their effectiveness in reducing the pore pressure build up as a function of their spacing. The soil was characterized by an advanced coupled soils constitutive model implemented in the Plaxis code: PM4sand. The input parameters for the model are evaluated on the basis of both laboratory element tests and centrifuge tests.

PARAMETRIC STUDY TO EVALUATE THE PERFORMANCE OF HORIZONTAL DRAINS AS MITIGATION TECHNIQUE AGAINST SOIL LIQUEFACTION / Fasano, Gianluca; Nappa, Valeria; Bilotta, Emilio; Flora, Alessandro. - (2019). (Intervento presentato al convegno 7th International Conference on Earthquake Geotechnical Engineering, (ICEGE 2019), June 17-20, 2019, Rome, Italy tenutosi a Roma (Italy) nel 17-20 June 2019) [10.5281/zenodo.3463477].

PARAMETRIC STUDY TO EVALUATE THE PERFORMANCE OF HORIZONTAL DRAINS AS MITIGATION TECHNIQUE AGAINST SOIL LIQUEFACTION.

gianluca fasano;valeria nappa;emilio bilotta;alessandro flora
2019

Abstract

In the framework of the LIQUEFACT project a series of centrifuge tests were conducted at ISMGEO (Italy) to verify the effectiveness of three mitigation techniques against soil liquefaction. This paper is focused on the study of horizontal drains as mitigation measure against liquefaction. The centrifuge layout with horizontal drains was numerically modelled and the change of boundary conditions reproduced by the FE code Plaxis 2D. Additionally, slightly different layouts from those tested in the centrifuge were also modelled to expand the scope of the experimental work. Horizontal drains were installed in the model, to analyse their effectiveness in reducing the pore pressure build up as a function of their spacing. The soil was characterized by an advanced coupled soils constitutive model implemented in the Plaxis code: PM4sand. The input parameters for the model are evaluated on the basis of both laboratory element tests and centrifuge tests.
2019
PARAMETRIC STUDY TO EVALUATE THE PERFORMANCE OF HORIZONTAL DRAINS AS MITIGATION TECHNIQUE AGAINST SOIL LIQUEFACTION / Fasano, Gianluca; Nappa, Valeria; Bilotta, Emilio; Flora, Alessandro. - (2019). (Intervento presentato al convegno 7th International Conference on Earthquake Geotechnical Engineering, (ICEGE 2019), June 17-20, 2019, Rome, Italy tenutosi a Roma (Italy) nel 17-20 June 2019) [10.5281/zenodo.3463477].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/776782
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact