BACKGROUND: Artificial genomic reference standards in a cytocentrifuge/cytospin format with well-annotated genomic data are useful for validating next-generation sequencing (NGS) on routine cytopreparations. Here, reference standards were optimized to be stained by different laboratories before DNA extraction and to contain a lower number of cells (2 × 105 ). This was done to better reflect the clinical challenge of working with insufficient cytological material. METHODS: A total of 17 worldwide laboratories analyzed customized reference standard slides (slides A-D). Each laboratory applied its standard workflow. The sample slides were engineered to harbor epidermal growth factor receptor (EGFR) c.2235_2249del15 p.E746_A750delELREA, EGFR c.2369C>T p.T790M, Kirsten rat sarcoma viral oncogene homolog (KRAS) c.38G>A p.G13D, and B-Raf proto-oncogene, serine/threonine kinase (BRAF) c.1798_1799GT>AA p.V600K mutations at various allele frequencies (AFs). RESULTS: EGFR and KRAS mutation detection showed excellent interlaboratory reproducibility, especially on slides A and B (10% and 5% AFs). On slide C (1% AF), either the EGFR mutation or the KRAS mutation was undetected by 10 of the 17 laboratories (58.82%). A reassessment of the raw data in a second-look analysis highlighted the mutations (n = 10) that had been missed in the first-look analysis. BRAF c.1798_1799GT>AA p.V600K showed a lower concordance rate for mutation detection and AF quantification. CONCLUSIONS: The data show that the detection of low-abundance mutations is still clinically challenging and may require a visual inspection of sequencing reads to detect. Genomic reference standards in a cytocentrifuge/cytospin format are a valid tool for regular quality assessment of laboratories performing molecular studies on cytology with low-AF mutations.

Consistency and reproducibility of next-generation sequencing in cytopathology: A second worldwide ring trial study on improved cytological molecular reference specimens / Pisapia, P., Malapelle, U., Roma, G., Saddar, S., Zheng, Q., Pepe, F., Bruzzese, D., Vigliar, E., Bellevicine, C., Luthra, R., Nikiforov, Y.E., Mayo-de-Las-Casas, C., Molina-Vila, M.A., Rosell, R., Bihl, M., Savic, S., Bubendorf, L., de Biase, D., Tallini, G., Hwang, D.H., et al.. - In: CANCER CYTOPATHOLOGY. - ISSN 1934-662X. - 127:5(2019), pp. 285-296. [10.1002/cncy.22134]

Consistency and reproducibility of next-generation sequencing in cytopathology: A second worldwide ring trial study on improved cytological molecular reference specimens

Pisapia P.;Malapelle U.;Pepe F.;Bruzzese D.;Vigliar E.;Bellevicine C.;Savic S.;RUGGE, LUIGI;Fontanini G.;
2019

Abstract

BACKGROUND: Artificial genomic reference standards in a cytocentrifuge/cytospin format with well-annotated genomic data are useful for validating next-generation sequencing (NGS) on routine cytopreparations. Here, reference standards were optimized to be stained by different laboratories before DNA extraction and to contain a lower number of cells (2 × 105 ). This was done to better reflect the clinical challenge of working with insufficient cytological material. METHODS: A total of 17 worldwide laboratories analyzed customized reference standard slides (slides A-D). Each laboratory applied its standard workflow. The sample slides were engineered to harbor epidermal growth factor receptor (EGFR) c.2235_2249del15 p.E746_A750delELREA, EGFR c.2369C>T p.T790M, Kirsten rat sarcoma viral oncogene homolog (KRAS) c.38G>A p.G13D, and B-Raf proto-oncogene, serine/threonine kinase (BRAF) c.1798_1799GT>AA p.V600K mutations at various allele frequencies (AFs). RESULTS: EGFR and KRAS mutation detection showed excellent interlaboratory reproducibility, especially on slides A and B (10% and 5% AFs). On slide C (1% AF), either the EGFR mutation or the KRAS mutation was undetected by 10 of the 17 laboratories (58.82%). A reassessment of the raw data in a second-look analysis highlighted the mutations (n = 10) that had been missed in the first-look analysis. BRAF c.1798_1799GT>AA p.V600K showed a lower concordance rate for mutation detection and AF quantification. CONCLUSIONS: The data show that the detection of low-abundance mutations is still clinically challenging and may require a visual inspection of sequencing reads to detect. Genomic reference standards in a cytocentrifuge/cytospin format are a valid tool for regular quality assessment of laboratories performing molecular studies on cytology with low-AF mutations.
2019
Consistency and reproducibility of next-generation sequencing in cytopathology: A second worldwide ring trial study on improved cytological molecular reference specimens / Pisapia, P., Malapelle, U., Roma, G., Saddar, S., Zheng, Q., Pepe, F., Bruzzese, D., Vigliar, E., Bellevicine, C., Luthra, R., Nikiforov, Y.E., Mayo-de-Las-Casas, C., Molina-Vila, M.A., Rosell, R., Bihl, M., Savic, S., Bubendorf, L., de Biase, D., Tallini, G., Hwang, D.H., et al.. - In: CANCER CYTOPATHOLOGY. - ISSN 1934-662X. - 127:5(2019), pp. 285-296. [10.1002/cncy.22134]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/757750
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 48
  • ???jsp.display-item.citation.isi??? 44
social impact