This study proposes an evaluation of the diffusive gradients in thin films technique (DGT) for studying trace elements in digested sewage sludge samples. Twelve elements were monitored by Chelex (Al, Cd, Co, Cr (III), Cu, Fe, Mn, Ni, Pb) and zirconia-DGT (As, Mo, Se) samplers exposed from 4 h to 9 days. Twenty-four hours’ deployment time was suitable for most of the studied elements. However, short deployment led to insufficient element accumulation or non-establishment of steady state while long deployment (from 18 to 144 h depending on the element) led to saturation of the binding gels and/or competing effects with other major elements. In addition, this study showed that the matrix of the digested sewage sludge lowers the accumulation of some trace elements in the DGT samplers, leading to labile concentrations underestimation of roughly 10–30% (depending on the element). Moreover, compared to the conventional total dissolved elements measurement, DGT technique allowed to quantify 7 out of 12 labile elements whereas only 3 out of 12 dissolved elements were quantified. These results highlight the potential of DGT technique to assess labile trace elements in digestate samples, provided a careful adaptation of the deployment time as well as an evaluation of the matrix effect is performed.

Assessment of the DGT technique in digestate to fraction twelve trace elements / Laera, Andreina; Buzier, Rémy; Guibaud, Gilles; Esposito, Giovanni; van Hullebusch, Eric D.. - In: TALANTA. - ISSN 0039-9140. - 192:(2019), pp. 204-211. [10.1016/j.talanta.2018.09.033]

Assessment of the DGT technique in digestate to fraction twelve trace elements

Esposito, Giovanni;
2019

Abstract

This study proposes an evaluation of the diffusive gradients in thin films technique (DGT) for studying trace elements in digested sewage sludge samples. Twelve elements were monitored by Chelex (Al, Cd, Co, Cr (III), Cu, Fe, Mn, Ni, Pb) and zirconia-DGT (As, Mo, Se) samplers exposed from 4 h to 9 days. Twenty-four hours’ deployment time was suitable for most of the studied elements. However, short deployment led to insufficient element accumulation or non-establishment of steady state while long deployment (from 18 to 144 h depending on the element) led to saturation of the binding gels and/or competing effects with other major elements. In addition, this study showed that the matrix of the digested sewage sludge lowers the accumulation of some trace elements in the DGT samplers, leading to labile concentrations underestimation of roughly 10–30% (depending on the element). Moreover, compared to the conventional total dissolved elements measurement, DGT technique allowed to quantify 7 out of 12 labile elements whereas only 3 out of 12 dissolved elements were quantified. These results highlight the potential of DGT technique to assess labile trace elements in digestate samples, provided a careful adaptation of the deployment time as well as an evaluation of the matrix effect is performed.
2019
Assessment of the DGT technique in digestate to fraction twelve trace elements / Laera, Andreina; Buzier, Rémy; Guibaud, Gilles; Esposito, Giovanni; van Hullebusch, Eric D.. - In: TALANTA. - ISSN 0039-9140. - 192:(2019), pp. 204-211. [10.1016/j.talanta.2018.09.033]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/741551
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact