In this paper, a model that analyses the coupling of a concentrating photovoltaic and thermal (CPV/T) system with a desiccant cooling (DC) system used to satisfy the energy loads required by a supermarket, is presented. A detailed analysis of the supermarket electrical and thermal loads is conducted in different periods of the year: summer, winter and half seasons. A CPV/T system linear focus configuration is considered, and its sizing as a function of the solar Direct Normal Irradiance (DNI) is realized for each period of the year. Hence, an Artificial Neural Network (ANN) is used to model carefully the DNI adopting experimental data in the simulation process. The coupling between the CPV/T and DC systems allows to obtain energy and economic savings during the year compared with a conventional solution, considering accurately in the modelling: supermarket energy loads, solar radiation, environmental conditions, etc. In particular, the analysis of three case studies is performed, where the main aim has been to size the CPV/T-DC integrated system and to study how it can match the different supermarket energy needs. The three solutions are analyzed from an energetic and economic point of view in order to demonstrate the effectiveness of the solution proposed.

Performance analysis of a CPV/T-DC integrated system adopted for the energy requirements of a supermarket / Carlo, Renno; D'Agostino, Diana; Minichiello, Francesco; Petito, Fabio; Igor, Balen. - In: APPLIED THERMAL ENGINEERING. - ISSN 1359-4311. - 149:(2019), pp. 231-248. [10.1016/j.applthermaleng.2018.12.007]

Performance analysis of a CPV/T-DC integrated system adopted for the energy requirements of a supermarket

Diana D'Agostino;Francesco Minichiello;PETITO, FABIO;
2019

Abstract

In this paper, a model that analyses the coupling of a concentrating photovoltaic and thermal (CPV/T) system with a desiccant cooling (DC) system used to satisfy the energy loads required by a supermarket, is presented. A detailed analysis of the supermarket electrical and thermal loads is conducted in different periods of the year: summer, winter and half seasons. A CPV/T system linear focus configuration is considered, and its sizing as a function of the solar Direct Normal Irradiance (DNI) is realized for each period of the year. Hence, an Artificial Neural Network (ANN) is used to model carefully the DNI adopting experimental data in the simulation process. The coupling between the CPV/T and DC systems allows to obtain energy and economic savings during the year compared with a conventional solution, considering accurately in the modelling: supermarket energy loads, solar radiation, environmental conditions, etc. In particular, the analysis of three case studies is performed, where the main aim has been to size the CPV/T-DC integrated system and to study how it can match the different supermarket energy needs. The three solutions are analyzed from an energetic and economic point of view in order to demonstrate the effectiveness of the solution proposed.
2019
Performance analysis of a CPV/T-DC integrated system adopted for the energy requirements of a supermarket / Carlo, Renno; D'Agostino, Diana; Minichiello, Francesco; Petito, Fabio; Igor, Balen. - In: APPLIED THERMAL ENGINEERING. - ISSN 1359-4311. - 149:(2019), pp. 231-248. [10.1016/j.applthermaleng.2018.12.007]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/737204
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 21
social impact