Classification of electrocardiographic (ECG) signals can be deteriorated by the presence in the training set of mislabeled samples. To alleviate this issue we propose a new approach that aims at assisting the human user (cardiologist) in his/her work of labeling by removing in an automatic way the training samples with potential mislabeling problems. The proposed method is based on a genetic optimization process, in which each chromosome represents a candidate solution for validating/invalidating the training samples. Moreover, the optimization process consists of optimizing jointly two different criteria, which are the maximization of the statistical separability among classes and the minimization of the number of invalidated samples. Experimental results obtained on real ECG signals extracted from the MIT-BIH arrhythmia database confirm the effectiveness of the proposed solution.
Genetic algorithm-based method for mitigating label noise issue in ECG signal classification / Pasolli, Edoardo; Melgani, Farid. - In: BIOMEDICAL SIGNAL PROCESSING AND CONTROL. - ISSN 1746-8094. - 19:(2015), pp. 130-136. [10.1016/j.bspc.2014.10.013]
Genetic algorithm-based method for mitigating label noise issue in ECG signal classification
Pasolli, Edoardo;
2015
Abstract
Classification of electrocardiographic (ECG) signals can be deteriorated by the presence in the training set of mislabeled samples. To alleviate this issue we propose a new approach that aims at assisting the human user (cardiologist) in his/her work of labeling by removing in an automatic way the training samples with potential mislabeling problems. The proposed method is based on a genetic optimization process, in which each chromosome represents a candidate solution for validating/invalidating the training samples. Moreover, the optimization process consists of optimizing jointly two different criteria, which are the maximization of the statistical separability among classes and the minimization of the number of invalidated samples. Experimental results obtained on real ECG signals extracted from the MIT-BIH arrhythmia database confirm the effectiveness of the proposed solution.File | Dimensione | Formato | |
---|---|---|---|
Pasolli_2015.pdf
solo utenti autorizzati
Tipologia:
Documento in Post-print
Licenza:
Accesso privato/ristretto
Dimensione
1.04 MB
Formato
Adobe PDF
|
1.04 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.