The decays of Po-214 into Pb-210 and of Po-212 into Pb-208 tagged by the previous decays from Bi-214 and Bi-212 have been studied inserting quartz vials inside the Counting Test Facility (CTF) at the underground laboratory in Gran Sasso (LNGS). We find that the mean lifetime of (214)po is (236.00 +/- 0.42(stat) +/- 0.15(syst)) us and that of Po-212 is (425.1 +/- 0.9(stat) +/- 1.2(syst)) ns. Our results are compatible with previous measurements, have a much better signal to background ratio, and reduce the overall uncertainties. (C) 2014 Elsevier Ltd. All rights reserved.
Lifetimes of Po-214 and Po-212 measured with Counting Test Facility at Gran Sasso National Laboratory / Miramonti, L.; Bellini, G.; Benziger, J.; Bick, D.; Bonfini, G.; Bravo, D.; Avanzini, M. Buizza; Caccianiga, B.; Cadonati, L.; Calaprice, F.; Carraro, C.; Cavalcante, P.; Chavarria, A.; Chubakov, V.; D'Angelo, D.; Davini, S.; Derbin, A.; Etenko, A.; Fomenko, K.; Franco, D.; Galbiati, C.; Gazzana, S.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Grandi, L.; Guardincerri, E.; Hardy, S.; Ianni, Aldo; Ianni, Andrea; Kobychev, V.; Korablev, D.; Korga, G.; Koshio, Y.; Kryn, D.; Laubenstein, M.; Lewke, T.; Lissia, M.; Litvinovich, E.; Loer, B.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Machulin, I.; Manecki, S.; Maneschg, W.; Mantovani, F.; Manuzio, G.; Meindl, Q.; Meroni, E.; Misiaszek, M.; Montanari, D.; Mosteiro, P.; Muratova, V.; Nisi, S.; Oberauer, L.; Obolensky, M.; Ortica, F.; Otis, K.; Pallavicini, M.; Papp, L.; Perasso, L.; Perasso, S.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Romani, A.; Rossi, N.; Sabelnikov, A.; Saldanha, R.; Salvo, C.; Schoenert, S.; Simgen, H.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Sukhotin, S.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Vignaud, D.; Vogelaar, R. B.; von Feilitzsch, F.; Winter, J.; Wojcik, M.; Wright, A.; Wurm, M.; Xhixha, G.; Xu, J.; Zaimidoroga, O.; Zavatarelli, S.; Zuzel, G.. - In: JOURNAL OF ENVIRONMENTAL RADIOACTIVITY. - ISSN 0265-931X. - 138:(2014), pp. 444-446. [10.1016/j.jenvrad.2014.02.025]
Lifetimes of Po-214 and Po-212 measured with Counting Test Facility at Gran Sasso National Laboratory
The decays of Po-214 into Pb-210 and of Po-212 into Pb-208 tagged by the previous decays from Bi-214 and Bi-212 have been studied inserting quartz vials inside the Counting Test Facility (CTF) at the underground laboratory in Gran Sasso (LNGS). We find that the mean lifetime of (214)po is (236.00 +/- 0.42(stat) +/- 0.15(syst)) us and that of Po-212 is (425.1 +/- 0.9(stat) +/- 1.2(syst)) ns. Our results are compatible with previous measurements, have a much better signal to background ratio, and reduce the overall uncertainties. (C) 2014 Elsevier Ltd. All rights reserved.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/716779
Citazioni
ND
ND
1
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.