Scrubbing with seawater is a reliable technology for flue-gas desulfurization in coal-fired power plants or in marine applications. The introduction of new regulations for emission control in Europe and the due increment of operational efficiency are pushing forward the optimization of scrubber's design, for which packing columns may be a better solution compared to spray columns. The design of a seawater scrubber mainly relies on a correct assessment of the equilibrium conditions and of the mass transfer coefficients in the absorber. In this work, experiments are performed on a model flue-gas (32 m(3).h(-1)) having a SO2 concentration in the range 500-2000 ppm(v), treated in a packed column filled with a structured packing (Mellapak 250X (R)) at 1 atm and 25 degrees C, with liquid-to-gas ratio between 1.06 and 3.44 kg.kg(-1). Three different absorbing solutions are investigated: (a) a seawater; (b) a basic solution obtained by adding 200 mg.L-1 NaOH solution to the seawater and (c) distilled water, used as benchmark. In order to analyze the packed column tests, SO2 equilibrium absorption tests at low concentrations (100-2000 ppmv) are carried out in a feed-batch reactor, using the same absorbing solutions tested in column tests. The experimental tests in packed column indicate that, for SO2 concentration as low as 500 ppm, an absorption efficiency above 98% can be achieved by using liquid-to-gas mass ratio about to 2.91 kg.kg(-1). In this condition, few differences appear among solutions (a) and (b). For the highest SO2 concentration (i.e. 2000 ppmv), a maximum of 85% efficiency is observed for liquid-to-gas mass ratio of 3.44 kg.kg(-1). Modeling of both the equilibrium and the dynamic data are implemented in Aspen Plus (R) V 8.6. However, while modeling assures a very good prediction of the equilibrium data, it is not able to properly describe the dynamic test results, with a systematic underestimation for tests having a removal efficiency higher than 85%.

Experimental and modelling analysis of seawater scrubbers for sulphur dioxide removal from flue-gas / Flagiello, Domenico; Erto, A.; Lancia, A.; Di Natale, F.. - In: FUEL. - ISSN 0016-2361. - 214:(2018), pp. 254-263. [https://doi.org/10.1016/j.fuel.2017.10.098]

Experimental and modelling analysis of seawater scrubbers for sulphur dioxide removal from flue-gas

FLAGIELLO, DOMENICO;Erto, A.
;
Lancia, A.;Di Natale, F.
2018

Abstract

Scrubbing with seawater is a reliable technology for flue-gas desulfurization in coal-fired power plants or in marine applications. The introduction of new regulations for emission control in Europe and the due increment of operational efficiency are pushing forward the optimization of scrubber's design, for which packing columns may be a better solution compared to spray columns. The design of a seawater scrubber mainly relies on a correct assessment of the equilibrium conditions and of the mass transfer coefficients in the absorber. In this work, experiments are performed on a model flue-gas (32 m(3).h(-1)) having a SO2 concentration in the range 500-2000 ppm(v), treated in a packed column filled with a structured packing (Mellapak 250X (R)) at 1 atm and 25 degrees C, with liquid-to-gas ratio between 1.06 and 3.44 kg.kg(-1). Three different absorbing solutions are investigated: (a) a seawater; (b) a basic solution obtained by adding 200 mg.L-1 NaOH solution to the seawater and (c) distilled water, used as benchmark. In order to analyze the packed column tests, SO2 equilibrium absorption tests at low concentrations (100-2000 ppmv) are carried out in a feed-batch reactor, using the same absorbing solutions tested in column tests. The experimental tests in packed column indicate that, for SO2 concentration as low as 500 ppm, an absorption efficiency above 98% can be achieved by using liquid-to-gas mass ratio about to 2.91 kg.kg(-1). In this condition, few differences appear among solutions (a) and (b). For the highest SO2 concentration (i.e. 2000 ppmv), a maximum of 85% efficiency is observed for liquid-to-gas mass ratio of 3.44 kg.kg(-1). Modeling of both the equilibrium and the dynamic data are implemented in Aspen Plus (R) V 8.6. However, while modeling assures a very good prediction of the equilibrium data, it is not able to properly describe the dynamic test results, with a systematic underestimation for tests having a removal efficiency higher than 85%.
2018
Experimental and modelling analysis of seawater scrubbers for sulphur dioxide removal from flue-gas / Flagiello, Domenico; Erto, A.; Lancia, A.; Di Natale, F.. - In: FUEL. - ISSN 0016-2361. - 214:(2018), pp. 254-263. [https://doi.org/10.1016/j.fuel.2017.10.098]
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S001623611731356X-main.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Accesso privato/ristretto
Dimensione 952.59 kB
Formato Adobe PDF
952.59 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/693880
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 74
  • ???jsp.display-item.citation.isi??? 60
social impact