The main drawbacks in the use of acetylcholinesterase-based biosensors are their susceptibility to inhibition by too many chemicals, their limited time-stability, and the constant need for a supply of substrates for the measurements. In order to offset these deficiencies, we have addressed our studies towards the thermophilic esterase 2 from A. acidocaldarious, which shows a high specificity and affinity towards organophosphates and a high resistance under raw operative conditions. In particular, we have investigated the possibility of measuring the binding of organophosphates to the protein by using a fluorescent probe covalently linked near the active site. We have produced a mutant where the serine 35, a residue located atthe entrance ofthe alcohol binding site, has been replaced by a cysteine residue. The addition of 1,5-IAEDANS as a fluorescent probe to the thiol group of the mutant-protein did not affect the capability of the enzyme to bind the paraoxon and its stability or instability over time. We have set up a continuous flow system based on a re-circulating solution of the probe-enzyme complex through a fluorimetric flow cell inside a spectrofluorimeter. The addition of paraoxon aliquots has been detected in real-time by measuring the fluorescence quenching of the probe-enzyme complex. The fluorescence signals, as well as the enzyme activity, were not affected by dilution and organic solvent addition. These results support the development of biosensing devices for the continuous monitoring of organophosphate compounds
Direct detection of organophosphate compounds in water by a fluorescence-based biosensing device / Carullo, Paola; Chino, Marco; Cetrangolo, Giovanni Paolo; Terreri, Sara; Lombardi, Angela; Manco, Giuseppe; Cimmino, Amelia; Febbraio, Ferdinando. - In: SENSORS AND ACTUATORS. B, CHEMICAL. - ISSN 0925-4005. - 255:(2018), pp. 3257-3266. [10.1016/j.snb.2017.09.152]
Direct detection of organophosphate compounds in water by a fluorescence-based biosensing device
Carullo, Paola;Chino, Marco;Lombardi, Angela;
2018
Abstract
The main drawbacks in the use of acetylcholinesterase-based biosensors are their susceptibility to inhibition by too many chemicals, their limited time-stability, and the constant need for a supply of substrates for the measurements. In order to offset these deficiencies, we have addressed our studies towards the thermophilic esterase 2 from A. acidocaldarious, which shows a high specificity and affinity towards organophosphates and a high resistance under raw operative conditions. In particular, we have investigated the possibility of measuring the binding of organophosphates to the protein by using a fluorescent probe covalently linked near the active site. We have produced a mutant where the serine 35, a residue located atthe entrance ofthe alcohol binding site, has been replaced by a cysteine residue. The addition of 1,5-IAEDANS as a fluorescent probe to the thiol group of the mutant-protein did not affect the capability of the enzyme to bind the paraoxon and its stability or instability over time. We have set up a continuous flow system based on a re-circulating solution of the probe-enzyme complex through a fluorimetric flow cell inside a spectrofluorimeter. The addition of paraoxon aliquots has been detected in real-time by measuring the fluorescence quenching of the probe-enzyme complex. The fluorescence signals, as well as the enzyme activity, were not affected by dilution and organic solvent addition. These results support the development of biosensing devices for the continuous monitoring of organophosphate compoundsFile | Dimensione | Formato | |
---|---|---|---|
Carullo et al_preprint.pdf
accesso aperto
Descrizione: postprint
Tipologia:
Documento in Post-print
Licenza:
Creative commons
Dimensione
2.33 MB
Formato
Adobe PDF
|
2.33 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.