In this work we present the results of full Geant4 and FLUKA simulations and comparison with dosimetry data of an electron LINAC of St. Maria Hospital located in Terni, Italy. The facility is being used primarily for radiotherapy and the goal of the present study is the detailed investigation of electron beam parameters to evaluate the possibility to use the e-LINAC (during time slots when it is not used for radiotherapy) to test the performance of detector systems, in particular those designed to operate in space. The critical beam parameters are electron energy, profile and flux available at the surface of device to be tested. The present work aims to extract these parameters from dosimetry calibration data available at the e-LINAC. The electron energy ranges from 4 MeV to 20 MeV. The dose measurements have been performed by using an Advanced Markus Chamber which has a small sensitive volume.

Full Geant4 and FLUKA simulations of an e-LINAC for its use in particle detectors performance tests / Alpat, B; Pilicer, E; Servoli, L; Menichelli, M; Tucceri, P; Italiani, M; Buono, E; DI CAPUA, Francesco. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 7:03(2012), pp. P03013-P03013. [10.1088/1748-0221/7/03/P03013]

Full Geant4 and FLUKA simulations of an e-LINAC for its use in particle detectors performance tests

DI CAPUA, FRANCESCO
2012

Abstract

In this work we present the results of full Geant4 and FLUKA simulations and comparison with dosimetry data of an electron LINAC of St. Maria Hospital located in Terni, Italy. The facility is being used primarily for radiotherapy and the goal of the present study is the detailed investigation of electron beam parameters to evaluate the possibility to use the e-LINAC (during time slots when it is not used for radiotherapy) to test the performance of detector systems, in particular those designed to operate in space. The critical beam parameters are electron energy, profile and flux available at the surface of device to be tested. The present work aims to extract these parameters from dosimetry calibration data available at the e-LINAC. The electron energy ranges from 4 MeV to 20 MeV. The dose measurements have been performed by using an Advanced Markus Chamber which has a small sensitive volume.
2012
Full Geant4 and FLUKA simulations of an e-LINAC for its use in particle detectors performance tests / Alpat, B; Pilicer, E; Servoli, L; Menichelli, M; Tucceri, P; Italiani, M; Buono, E; DI CAPUA, Francesco. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 7:03(2012), pp. P03013-P03013. [10.1088/1748-0221/7/03/P03013]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/667784
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact