Recent European earthquakes demonstrated that the seismic response ofRCprecast structures can be significantly influenced by the connection systems. Moreover, during past seismic events, many failures of the beam-to-column connections occurred due to their inadequate strength under seismic loads. The seismic safety of these connections has a crucial role in the overall seismic capacity of existing precast structures. A new connection system is employed as a retrofitting solution for a damaged beam-to-column connection and its cyclic shear performance is investigated by means of two cyclic shear tests on two different configurations. In both the experimental tests, the results demonstrate an efficient behavior of the retrofitted connections under horizontal cyclic loads. The comparison between the performance of the investigated connection and the response of a typical beam-to-column dowel connection allows to discuss the main critical features of the dowel connection system.

Cyclic shear tests on RC precast beam-to-column connections retrofitted with a three-hinged steel device / Magliulo, Gennaro; Cimmino, Maddalena; Ercolino, Marianna; Manfredi, Gaetano. - In: BULLETIN OF EARTHQUAKE ENGINEERING. - ISSN 1570-761X. - 15:9(2017), pp. 3797-3817. [10.1007/s10518-017-0114-x]

Cyclic shear tests on RC precast beam-to-column connections retrofitted with a three-hinged steel device

MAGLIULO, GENNARO;CIMMINO, MADDALENA;ERCOLINO, MARIANNA;MANFREDI, GAETANO
2017

Abstract

Recent European earthquakes demonstrated that the seismic response ofRCprecast structures can be significantly influenced by the connection systems. Moreover, during past seismic events, many failures of the beam-to-column connections occurred due to their inadequate strength under seismic loads. The seismic safety of these connections has a crucial role in the overall seismic capacity of existing precast structures. A new connection system is employed as a retrofitting solution for a damaged beam-to-column connection and its cyclic shear performance is investigated by means of two cyclic shear tests on two different configurations. In both the experimental tests, the results demonstrate an efficient behavior of the retrofitted connections under horizontal cyclic loads. The comparison between the performance of the investigated connection and the response of a typical beam-to-column dowel connection allows to discuss the main critical features of the dowel connection system.
2017
Cyclic shear tests on RC precast beam-to-column connections retrofitted with a three-hinged steel device / Magliulo, Gennaro; Cimmino, Maddalena; Ercolino, Marianna; Manfredi, Gaetano. - In: BULLETIN OF EARTHQUAKE ENGINEERING. - ISSN 1570-761X. - 15:9(2017), pp. 3797-3817. [10.1007/s10518-017-0114-x]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/666599
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 15
social impact