In this study three-dimensional numerical models were refined to predict reactive processes in disinfection contact tanks (CTs). The methodology departs from the traditional performance assessment of contact tanks via hydraulic efficiency indicators, as it simulates directly transport and decay of the disinfectant, inactivation of pathogens and accumulation of by-products. The method is applied to study the effects of inlet and compartment design on contact tank performance, with special emphasis on turbulent mixing and minimisation of internal recirculation and short-circuiting. In contrast to the conventional approach of maximising the length-to-width ratio, the proposed design changes are aimed at addressing and mitigating adverse hydrodynamic structures, which have historically led to poor hydraulic efficiency in many existing contact tanks. The results suggest that water treatment facilities can benefit from in-depth analyses of the flow and kinetic processes through computational fluid dynamics, resulting in up to 38% more efficient pathogen inactivation and 14% less disinfection by-product formation.

Contact Tank Design Impact on Process Performance / Angeloudis, Athanasios; Stoesser, Thorsten; Gualtieri, Carlo; Falconer, Roger A.. - In: ENVIRONMENTAL MODELING & ASSESSMENT. - ISSN 1420-2026. - 21:5(2016), pp. 563-576. [10.1007/s10666-016-9502-x]

Contact Tank Design Impact on Process Performance

GUALTIERI, CARLO
Writing – Review & Editing
;
2016

Abstract

In this study three-dimensional numerical models were refined to predict reactive processes in disinfection contact tanks (CTs). The methodology departs from the traditional performance assessment of contact tanks via hydraulic efficiency indicators, as it simulates directly transport and decay of the disinfectant, inactivation of pathogens and accumulation of by-products. The method is applied to study the effects of inlet and compartment design on contact tank performance, with special emphasis on turbulent mixing and minimisation of internal recirculation and short-circuiting. In contrast to the conventional approach of maximising the length-to-width ratio, the proposed design changes are aimed at addressing and mitigating adverse hydrodynamic structures, which have historically led to poor hydraulic efficiency in many existing contact tanks. The results suggest that water treatment facilities can benefit from in-depth analyses of the flow and kinetic processes through computational fluid dynamics, resulting in up to 38% more efficient pathogen inactivation and 14% less disinfection by-product formation.
2016
Contact Tank Design Impact on Process Performance / Angeloudis, Athanasios; Stoesser, Thorsten; Gualtieri, Carlo; Falconer, Roger A.. - In: ENVIRONMENTAL MODELING & ASSESSMENT. - ISSN 1420-2026. - 21:5(2016), pp. 563-576. [10.1007/s10666-016-9502-x]
File in questo prodotto:
File Dimensione Formato  
EMA 2016 - Printed.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 3.61 MB
Formato Adobe PDF
3.61 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/656653
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 27
social impact