Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
Phase-rectified signal averaging, an innovative signal processing technique, can be used to investigate quasi-periodic oscillations in noisy, nonstationary signals that are obtained from fetal heart rate. Phase-rectified signal averaging is currently the best method to predict survival after myocardial infarction in adult cardiology. Application of this method to fetal medicine has established significantly better identification than with short-term variation by computerized cardiotocography of growth-restricted fetuses.
Phase-rectified signal averaging method to predict perinatal outcome in infants with very preterm fetal growth restriction- a secondary analysis of TRUFFLE-trial / Lobmaier, S.M., Mensing van Charante, N., Ferrazzi, E.M., Giussani, D.A., Shaw, C.J., Müller, A., Ortiz, J.U., Ostermayer, E., Haller, B., Prefumo, F., Frusca, T., Hecher, K., Arabin, B., Thilaganathan, B., Papageorghiou, A.T., Bhide, A., Martinelli, P., Duvekot, J.J., van Eyck, J., Visser, G.H.A., et al.. - In: AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY. - ISSN 0002-9378. - (2016). [10.1016/j.ajog.2016.06.024]
Phase-rectified signal averaging method to predict perinatal outcome in infants with very preterm fetal growth restriction- a secondary analysis of TRUFFLE-trial
Lobmaier, Silvia M;Mensing van Charante, Nico;FERRAZZI, ENRICO MARIO;Giussani, Dino A;Shaw, Caroline J;Müller, Alexander;Ortiz, Javier U;Ostermayer, Eva;Haller, Bernhard;Prefumo, Federico;Frusca, Tiziana;Hecher, Kurt;Arabin, Birgit;Thilaganathan, Baskaran;Papageorghiou, Aris T;Bhide, Amarnath;MARTINELLI, PASQUALE;Duvekot, Johannes J;van Eyck, Jim;Visser, Gerard H. A;Schmidt, Georg;Ganzevoort, Wessel;Lees, Christoph C;Schneider, Karl T. M.
2016
Abstract
Phase-rectified signal averaging, an innovative signal processing technique, can be used to investigate quasi-periodic oscillations in noisy, nonstationary signals that are obtained from fetal heart rate. Phase-rectified signal averaging is currently the best method to predict survival after myocardial infarction in adult cardiology. Application of this method to fetal medicine has established significantly better identification than with short-term variation by computerized cardiotocography of growth-restricted fetuses.
Phase-rectified signal averaging method to predict perinatal outcome in infants with very preterm fetal growth restriction- a secondary analysis of TRUFFLE-trial / Lobmaier, S.M., Mensing van Charante, N., Ferrazzi, E.M., Giussani, D.A., Shaw, C.J., Müller, A., Ortiz, J.U., Ostermayer, E., Haller, B., Prefumo, F., Frusca, T., Hecher, K., Arabin, B., Thilaganathan, B., Papageorghiou, A.T., Bhide, A., Martinelli, P., Duvekot, J.J., van Eyck, J., Visser, G.H.A., et al.. - In: AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY. - ISSN 0002-9378. - (2016). [10.1016/j.ajog.2016.06.024]
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/636026
Citazioni
ND
35
292
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.