Nonstructural components (NSCs) should be subjected to a careful and rational seismic design, in order to reduce the economic loss and to avoid threats to the life safety, as well as what concerns structural elements. The design of NSCs is based on the evaluation of the maximum inertia force, which is related to the floor spectral accelerations. The question arises as to whether Eurocode 8 is able to predict actual floor response spectral accelerations occurring in structures designed according to Eurocode 8. A parametric study is conducted on five RC frame structures in order to evaluate the floor response spectra. The structures, designed according to Eurocode 8, are subjected to a set of earthquakes, compatible with the design response spectrum. Time-history analyses are performed both on elastic and inelastic models of the considered structures. Eurocode formulation for the evaluation of the seismic demand on NSCs does not well fit the numerical results. Some comments on the target spectrum provided by AC 156 for the seismic qualification of NSC are also included.

Floor response spectra in RC frame structures designed according to Eurocode 8 / Petrone, Crescenzo; Magliulo, Gennaro; Manfredi, Gaetano. - In: BULLETIN OF EARTHQUAKE ENGINEERING. - ISSN 1570-761X. - 14:3(2016), pp. 747-767. [10.1007/s10518-015-9846-7]

Floor response spectra in RC frame structures designed according to Eurocode 8

PETRONE, CRESCENZO;MAGLIULO, GENNARO;MANFREDI, GAETANO
2016

Abstract

Nonstructural components (NSCs) should be subjected to a careful and rational seismic design, in order to reduce the economic loss and to avoid threats to the life safety, as well as what concerns structural elements. The design of NSCs is based on the evaluation of the maximum inertia force, which is related to the floor spectral accelerations. The question arises as to whether Eurocode 8 is able to predict actual floor response spectral accelerations occurring in structures designed according to Eurocode 8. A parametric study is conducted on five RC frame structures in order to evaluate the floor response spectra. The structures, designed according to Eurocode 8, are subjected to a set of earthquakes, compatible with the design response spectrum. Time-history analyses are performed both on elastic and inelastic models of the considered structures. Eurocode formulation for the evaluation of the seismic demand on NSCs does not well fit the numerical results. Some comments on the target spectrum provided by AC 156 for the seismic qualification of NSC are also included.
2016
Floor response spectra in RC frame structures designed according to Eurocode 8 / Petrone, Crescenzo; Magliulo, Gennaro; Manfredi, Gaetano. - In: BULLETIN OF EARTHQUAKE ENGINEERING. - ISSN 1570-761X. - 14:3(2016), pp. 747-767. [10.1007/s10518-015-9846-7]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/629401
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 57
social impact