Surgical repair of popliteal artery aneurysm in morbid obese patients poses additional challenges. We report a morbid obese patient who had a 59 mm right popliteal artery aneurysm which was successfully treated with the endograft connector technique. This technique was used to perform the distal anastomosis of the below-knee femoro-popliteal bypass. A 10 mm Dacron graft was used as a main graft bypass and an 11 mm/10 cm stentgraft as endograft connector. Following the respective tunnel of the Dacron graft, an end-to-side proximal anastomosis was performed at distal femoral artery. The aneurysm exclusion was obtained through a proximal and a distal ligation. Postoperative duplex showed adequate bypass patency. Knee x-rays demonstrated no signs of stent kinking/fractures. The postoperative course was uneventful and the patient was discharged home on fourth day post operative. The six-month computed tomography scan and the 12-month duplex control showed a patent bypass with no signs of stenosis.

Endograft connector technique to treat popliteal artery aneurysm in a morbid obese patient / Pecoraro, Felice; Bajardi, Guido; Dinoto, Ettore; Vitale, Gaetano; Bellisi, Mario; Bracale, UMBERTO MARCELLO. - In: VASCULAR. - ISSN 1708-5381. - 23:2(2015), pp. 165-169. [10.1177/1708538114533961]

Endograft connector technique to treat popliteal artery aneurysm in a morbid obese patient

BRACALE, UMBERTO MARCELLO
2015

Abstract

Surgical repair of popliteal artery aneurysm in morbid obese patients poses additional challenges. We report a morbid obese patient who had a 59 mm right popliteal artery aneurysm which was successfully treated with the endograft connector technique. This technique was used to perform the distal anastomosis of the below-knee femoro-popliteal bypass. A 10 mm Dacron graft was used as a main graft bypass and an 11 mm/10 cm stentgraft as endograft connector. Following the respective tunnel of the Dacron graft, an end-to-side proximal anastomosis was performed at distal femoral artery. The aneurysm exclusion was obtained through a proximal and a distal ligation. Postoperative duplex showed adequate bypass patency. Knee x-rays demonstrated no signs of stent kinking/fractures. The postoperative course was uneventful and the patient was discharged home on fourth day post operative. The six-month computed tomography scan and the 12-month duplex control showed a patent bypass with no signs of stenosis.
2015
Endograft connector technique to treat popliteal artery aneurysm in a morbid obese patient / Pecoraro, Felice; Bajardi, Guido; Dinoto, Ettore; Vitale, Gaetano; Bellisi, Mario; Bracale, UMBERTO MARCELLO. - In: VASCULAR. - ISSN 1708-5381. - 23:2(2015), pp. 165-169. [10.1177/1708538114533961]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/614234
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 14
social impact