The Cold-Formed Steel (CFS) structures are able to ensure a good structural response in seismic areas. Among them, the stick-built constructions raise a considerable interest in recent studies. In these structures, the lateral load bearing systems are CFS stud walls, that are generally realized with a frame in CFS profiles that can be braced by light gauge steel straps installed in an X configuration. In this case, the "all steel" design methodology can be adopted and the lateral resisting system is assured by the CFS strap-braced stud walls.
Seismic behaviour of "all-steel" CFS structures: experimental tests / Pali, T., Iuorio, O., Macillo, V., Terracciano, M.T., Fiorino, L., Landolfo, R.. - (2014), pp. 33-648-1-33-648-8. (7th European Conference on Steel and Composite Structures Napoli 10-12 settembre 2014).
Seismic behaviour of "all-steel" CFS structures: experimental tests
PALI, TATIANA;IUORIO, Ornella;MACILLO, VINCENZO;TERRACCIANO, MARIA TERESA;FIORINO, Luigi;LANDOLFO, RAFFAELE
2014
Abstract
The Cold-Formed Steel (CFS) structures are able to ensure a good structural response in seismic areas. Among them, the stick-built constructions raise a considerable interest in recent studies. In these structures, the lateral load bearing systems are CFS stud walls, that are generally realized with a frame in CFS profiles that can be braced by light gauge steel straps installed in an X configuration. In this case, the "all steel" design methodology can be adopted and the lateral resisting system is assured by the CFS strap-braced stud walls.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.