Oriented antibodies are tethered on the gold surface of a quartz crystal microbalance through the photonics immobilization technique so that limit of detection as low as 50 nM and 140 nM are achieved for parathion and patulin, respectively. To make these small analytes detectable by the microbalance, they have been weighed down through a “sandwich protocol” with a second antibody. The specificity against the parathion has been tested by checking the immunosensor response to a mixture of compounds similar to parathion, whereas the specificity against the patulin has been tested with a real sample from apple puree. In both cases, the results are more than satisfactory suggesting interesting outlook for the proposed device.

Detection of parathion and patulin by quartz-crystal microbalance functionalized by the photonics immobilization technique / Funari, Riccardo; DELLA VENTURA, Bartolomeo; Raffaele, Carrieri; Luigi, Morra; Ernesto, Lahoz; Gesuele, Felice; Altucci, Carlo; Velotta, Raffaele. - In: BIOSENSORS & BIOELECTRONICS. - ISSN 0956-5663. - 67:(2015), pp. 224-229. [10.1016/j.bios.2014.08.020]

Detection of parathion and patulin by quartz-crystal microbalance functionalized by the photonics immobilization technique

FUNARI, RICCARDO;Bartolomeo Della Ventura;GESUELE, FELICE;ALTUCCI, CARLO;VELOTTA, RAFFAELE
2015

Abstract

Oriented antibodies are tethered on the gold surface of a quartz crystal microbalance through the photonics immobilization technique so that limit of detection as low as 50 nM and 140 nM are achieved for parathion and patulin, respectively. To make these small analytes detectable by the microbalance, they have been weighed down through a “sandwich protocol” with a second antibody. The specificity against the parathion has been tested by checking the immunosensor response to a mixture of compounds similar to parathion, whereas the specificity against the patulin has been tested with a real sample from apple puree. In both cases, the results are more than satisfactory suggesting interesting outlook for the proposed device.
2015
Detection of parathion and patulin by quartz-crystal microbalance functionalized by the photonics immobilization technique / Funari, Riccardo; DELLA VENTURA, Bartolomeo; Raffaele, Carrieri; Luigi, Morra; Ernesto, Lahoz; Gesuele, Felice; Altucci, Carlo; Velotta, Raffaele. - In: BIOSENSORS & BIOELECTRONICS. - ISSN 0956-5663. - 67:(2015), pp. 224-229. [10.1016/j.bios.2014.08.020]
File in questo prodotto:
File Dimensione Formato  
Funari_BB_2015.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Documento in Post-print
Licenza: Dominio pubblico
Dimensione 1.1 MB
Formato Adobe PDF
1.1 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/588387
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 83
  • ???jsp.display-item.citation.isi??? 74
social impact